35
Control
ENG
Deactivating the operating mode "Com-
bined operation WHITE+RGB"
Bit 2
Bit 1
Bit 0
10 ms
1
0
1
0
1
0
Fig. 9: Bit sequence to deactivate the operating
mode "Combined operation WHITE+RGB“.
NOTE:
The bit sequence consists of three
bits. The corresponding bit length must be
in a range between 8 ms and 12 ms.
X
Send the bit sequence for deactivation
to the connection cable with the white
luminaires and the RGB luminaire, see
Fig. 9.
The operating mode will be changed.
The white luminaires will light up
shortly. For a short time, the RGB lumi-
naire will light up in red, then in green
and will go off afterwards.
The operating mode "Combined oper-
ation WHITE+RGB" is now deactivated
for all luminaires which are connected
to the connection cable.
The luminaires are in normal mode.