background image

 

500.0024-A

 

Subject to technical changes

 

 

Overview

 

The Paxos Advance is installed in the WALDIS First and WALDIS Premium series of 
models. Because of their high security class, this is the only lock that is allowed to be 
installed in these series of models. Users find that the display makes it easy and clear to 
operate. Various additional functions can also be used with the Paxos Advance. 
 

1.1.

 

Operating controls: WALDIS First and Premium

 

 
 
 
 
Input unit 
 
 
 
 
 
Rotary opening handle 
 
 
 
 
 
 
 
 
 

  

 

 

 

NOTE:

 These operating instructions describe how to handle a safe; in each case, they 

show a version with the hinge on the right-hand side of the door. If you have a safe with 
the hinge on the left-hand side of the door, you need to perform all the turning, opening 
and closing movements in the opposite direction! 
 
 
 
 

 

 

Summary of Contents for PAXOS ADVANCE DUAL LOCK

Page 1: ...www tresore ch OPERATING INSTRUCTIONS SAFE LOCK PAXOS ADVANCE DUAL LOCK Electronic safe lock for WA safes...

Page 2: ...the EN1143 1 standard A Swiss quality product with security tested by the VdS German Association of Indemnity Insurers Before starting to use your strongbox please read these instructions thoroughly...

Page 3: ...ramming codes 7 3 4 1 User code 01 OCa1 and user code 02 OCb1 for lock 1 7 3 4 2 User code 01 OCa2 and user code 02 OCb2 for lock 2 8 3 4 3 Master code 00 MA1 8 3 4 4 Master code 00 MA2 9 3 5 Setting...

Page 4: ...s it easy and clear to operate Various additional functions can also be used with the Paxos Advance 1 1 Operating controls WALDIS First and Premium Input unit Rotary opening handle NOTE These operatin...

Page 5: ...l Pos 3 Arrow key up left Select the next menu item Select the next input value Pos 4 Arrow key down right Select the next menu item Select the next input value Pos 5 ENTER key Confirm inputs Call up...

Page 6: ...to release the battery case that is slotted into the input unit from below and swivel it downwards and outwards 3 The battery holder B is inserted in the battery case release it from the case and fit...

Page 7: ...ate time saved message 8 Press the ENTER key repeatedly and the display will show the Open menu message confirm this again with the ENTER key 9 The display shows the Lock code 1 message to indicate th...

Page 8: ...the display shows the Lock 1 is opening message followed by Lock is open The display then shows the Lock code 2 message to indicate that user code 1 or 2 for lock 2 12223310 or 12223320 must be enter...

Page 9: ...alarm which cannot be heard at your location can be sent to the alarm centre when the code to open the safe is entered in the normal way To trigger the threat alarm the value of the last two digits of...

Page 10: ...99 88 77 Battery code BC94 11 11 11 11 The lock cannot be opened with this code it is needed to define the employee codes and the time functions The Paxos Advance electronic high security lock is norm...

Page 11: ...pressing the ENTER key again 4 On the display use the arrow key to select Lock 2 and also confirm this with the ENTER key 5 Use any arrow key to select 01 OCa2 02 OCb2 and confirm with the ENTER key t...

Page 12: ...current codes 2 Leave the rotary opening handle in the open position 3 On the input unit press the ENTER key confirm the Code functions menu that is shown on the display by pressing the ENTER key aga...

Page 13: ...ine batteries LR6 E91 or AM3 into it As an option you can also insert a rechargeable battery pack A from Dorma Kaba in this case there is no need for the battery holder Operation with rechargeable bat...

Page 14: ...ossible section 3 6 The lock can be operated until the battery voltage drops below 6 5 volts No codes or settings are deleted when a battery is replaced You only need to check the date and time and re...

Page 15: ...ff 5 1 Assignment of terminals on the I O box The I O box has 8 inputs and 8 outputs connections for the power supply and an RS232 interface NOTE The I O box functions are only available when the I O...

Page 16: ...on Connection with tamper monitoring switch factory configuration 3 IN2 4 GND Input 2 Standard bypass opening delay 5 IN3 6 GND Input 3 Standard interrupt lockout time 16 IN4 17 GND Input 4 Standard e...

Page 17: ...at 50 C ext OUTx OUTx 9 OUT2 10 OUT2 Output 2 Standard all locks and door bolts open 11 OUT3 12 OUT3 Output 3 Standard resistance monitoring input sabotaged 22 OUT4 23 OUT4 Output 4 Standard external...

Page 18: ...itoring of external power supply Output voltage 24 VAC power load at output 0 4 A at 25 C 0 3 A at 50 C ext NC 39 COM 40 NO 41 14 VDC 15 GND External power supply 12 VDC 24 VDC 700 200 mA ext I O box...

Page 19: ...as far as possible the keypad shows signs of wear over time revealing the individual numbers used in the code Example of a good password Memorable sentence First letters of each word First letters in...

Reviews: