![Waldbeck 10031571 Manual Download Page 12](http://html1.mh-extra.com/html/waldbeck/10031571/10031571_manual_3182366012.webp)
12
Cleaning and Care
• Remove the mains plug before all maintenance work.
• In the event that the pump is often transported in the course of operation, it should be
cleaned out with clear water after every use.
• In case of stationary installation, the function of the loading switch should be checked
every 3 months.
•
All fibrous particles which may have built-up inside the pump housing should be removed
with a water jet.
• Every 3 months the shaft ground and as should be cleaned from mud.
•
Remove deposits on the floater with clear water.
Troubleshooting
Problem
Possible Cause
Suggested Solution
Pump does not start.
Power supply not
connected.
Check power supply.
Floater does not switch.
Raise position of floating switch.
No flow.
Inlet sieve is clogged.
Clean inlet sieve.
Pressure hose in bent.
Reset hose.
Pump does not switch
off.
Floater cannot sink down.
Place pump properly on shaft
ground
Insufficient flow.
Inlet sieve is clogged.
Clean inlet sieve.
Reduced pumping capacity
by dirty and abrasive water.
Clean pump and shaft bottom.
Pump switches of
after short operating
period.
Thermal cutout stops
pumps due to dirty water.
Remove mains plug. Clean pump
and shaft
Water too hot. Thermal
cutout stops pump.
Make sure that water temperature
of max. 35°C is not exceed
Summary of Contents for 10031571