TROUBLESHOOTING

SYMPTOM “A”: NO HEAT - INDICATOR LIGHT OFF

1) ELECTRIC SUPPLY IS OFF
Turn on the main circuit breaker.

2) NO OR LOW WATER FLOW 
Ensure that the minimum flow rate to switch on your heater is met. 
T, TC Models – 0.75gpm
T2 Models – 1.5gpm
P2 Models – 1.5gpm  
Also check that the inlet filter screen is clear from any
debris. This is located in the brass inlet boss.

3) WATER CONNECTIONS ARE REVERSED
Cold water inlet = right side, hot water outlet = left side.

4) ELEMENT BURNED OUT
TURN OFF THE  MAIN CIRCUIT BREAKER!
Using an ohmmeter test the resistance of the heating element
across the two threaded termination rods on top of the element.
The resistance reading should be under 10 ohms. If the resistance
is much greater than this value, call Waiwela for a replacement element.

5) ECO TRIPPED (High Limit Thermostat)
TURN OFF THE MAIN CIRCUIT BREAKER!
Reset by pushing in red button on each heater module.

SYMPTOM “B”: NO HEAT OR LOW TEMPERATURE WITH INDICATOR LIGHT ON

1) WATER FLOW TOO HIGH
Reduce the water flow by using an outlet ball valve. See page 8 for temperature rise at various
flow rates.

2) INCORRECT POWER SUPPLY
Make sure that the unit is connected to the voltage supply specified on the rating label on the
front cover of the unit and no other.

3) ELEMENT BURNED OUT
TURN OFF THE MAIN CIRCUIT BREAKER!
Repeat the steps from paragraph 4 above.

4)THERMOSTAT ADJUSTMENT SCREW NOT TURNED UP (Models “T”, “TC” and “T2” only.)
Turn both thermostat adjustment screws clockwise in small increments until the indicator light(s)
remains on.  Take care not to force the screw past it’s stop position.  

5) ECO TRIPPED (High Limit Thermostat)
See Paragraph 5 above.

9

Summary of Contents for WET-12 T

Page 1: ...OPERLY AND IT COULD CAUSE DEATH SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE READ ALSO THE ENCLOSED WARRANTY CARD WARRANTY OF THIS WATER HEATER WILL DEPEND ON PROPER INSTALLATION AND OPERATION THE WAR...

Page 2: ...USTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE REFER TO THIS MANUAL FOR ASSISTANCE OR CONSULT THE LOCAL ELECTRIC UTILITY FOR FURTHER INFORMATION FAI...

Page 3: ...CLEARANCE ABOVE UNIT 3 Figure 1 MOUNTING HOLES To independent circuit breaker serial LUG TERMINALS AT RELAYS ELECTRICAL HOOK UP 240V 208V L1 L2 L1 L2 GROUND LUG Factory installed jumpers from L1 L1 a...

Page 4: ...nd side Under NO circumstances can these be reversed 4 Leave a minimum of 8 above the unit for easy replacement of the element 5 The heater should be fixed to the wall using screws in the four mountin...

Page 5: ...es full flow ball valve type on both inlet and outlet pipes This allows unit to be isolated for maintenance purposes Fig 1 4 When all plumbing is complete fully check the system for water leaks at all...

Page 6: ...rough the hole provided in the flange on the backplate The live wires should be connected to the slots in the terminal block marked L1 and L2 The ground lead must be connected to the slot marked GND G...

Page 7: ...first unit is the right hand heating module and the second unit is the left hand heating module IV COMMISSIONING YOUR HEATER T MODELS a Switch on the power to the first unit The power indicator light...

Page 8: ...adjustment screws by about the same amount so that the lights pulse at the same rate If you have reduced the temperature considerably from the 125 F setting you could now open up the outlet ball valve...

Page 9: ...an this value call Waiwela for a replacement element 5 ECO TRIPPED High Limit Thermostat TURN OFF THE MAIN CIRCUIT BREAKER Reset by pushing in red button on each heater module SYMPTOM B NO HEAT OR LOW...

Page 10: ...MBLY EX1000 5 75KW 240V 7 Wire EX 100G 8 Wire EX 284 WaiWela 5350 Joliet St 2 Denver CO 80239 Tel 1 800 543 6163 To appropriate circuit breaker 10 Triac EX 18 WAIWELA REPLACEMENT PARTS DIAGRAM CONTROL...

Page 11: ...L L1 BLK ELEMENT RING TRIAC GATE BLK POWER BLK L1 FROM RELAY LINE SIDE T C BLU T C BLU RELAY ORG TO ECO EL L2 N RED or WHT ELEMENT RING T C BLU 2 PIN CONNECTOR RELAY ORG TO RELAY COIL L1 POWER BLK FRO...

Reviews: