background image

Draining the Water Heater

WARNING: Failure 

to drain the water heater 

can cause serious 

damage to the water 

heater as well as 

personal injury.

Below are instructions for draining water out 

of the water heater .

  

Turn off the switch on the remote control .

  Close the gas shut-off valve(s) .
  Unplug the power supply cord (or 

disconnect breaker) at least 10 seconds 

after step #1 .

  Open all hot water faucets . Before 

proceeding to the next step, make sure that 

COLD water is coming out of all hot water 

faucets .

  Close the water shut-off valve .
  Using a suitable container to catch water, 

remove the water filter and the drain valve 

from heater . Attach a garden hose to the 

drain valve installed in the hot water outlet 

line and direct the stream of water to a 

suitable drain where it will cause no 

damage . Leave water heater as is until next 

use .

To put the water heater back into operation 

after draining, follow the steps below .

  

Reinstall the drain valve and the water 

filter . Close the hot water outlet drain 

valve .

  Open the water shut-off valve and close 

again after making sure that water comes 

out from hot water faucets . (This step is to 

remove air from the water lines .)

  Plug into an electrical outlet, fully open 

the gas shut-off valve and the water  

shut-off valve .

NOTICE:

 The water heater may not 

operate unless the above procedure is 

followed correctly .

Draining the water heater

WARNING: Failure 

to follow these 

instructions while 

draining the water 

heater can cause serious 

damage to the water 

heater as well as 

personal injury, 

including scalding.

NOTICE: DO NOT 

unplug the electric 

power supply cord for 

freeze protection.

Care and cleaning of the water heater:

Freeze Protection

Where the water heater may be exposed to 

freezing conditions, even for a short period of 

time, be sure to drain all water from the unit 

as instructed above .
Exposure to freezing conditions can occur 

from down draft of venting system or from 

installation in areas exposed to cold air .
The water heater is equipped with a Freeze 

Protection Electric Heater . As long as electricity 

is supplied to the water heater, it prevents 

freezing inside the water heater down to an 

ambient temperature of approximately  

minus 30°F (-34°C) (without wind conditions) .
This device only protects the internal 

components of the water heater . It does NOT 

protect piping and valves . Therefore, piping 

and valves should be wrapped with insulation 

material as instructed on page 19 .

Another method of freeze prevention is by 

running a small volume of water . Running 

water will protect the water heater, piping  

and valves .
Follow the steps below to ensure proper water 

flow through the water heater and piping:

  

Turn off the switch on the remote control .

  Close the gas shut-off valve .
  Open the hot water faucet slightly until a 

stream of approximately 1/8” ( .32 cm) is 

flowing . Be sure to check the flow 

periodically .

Water Inlet

Water Outlet

Drain

Pressure Relief valve

Hot Water Service valve

Cold Water Service 

valve

Optional Maintenance Method

Isolator valve kits may be purchased as optional 

items from manufacturer, distributor or place  

of purchase . They allow for one person full 

diagnostic testing and ease of flushing the 

system .
The kit includes two full port isolation valves, 

one for the cold side and one for the hot side .

CAUTION: Even when 

drained properly, a small 

amount of water will remain 

in the water heater. In cold 

weather, conditions this water 

can freeze. If this happens 

allow the defrost protection 

on the heater at least 30 

minutes to melt the frozen 

water or the water heater 

may not work properly.

26

¥

F

PRIORITY

POWER

ON/OFF

Summary of Contents for SCT150X

Page 1: ...proper installation and adjustment of the water heater and two to the owner operator to explain the features operation safety precautions maintenance and troubleshooting of the water heater This manu...

Page 2: ...heater You ll find many answers to common problems in the Troubleshooting Guide If you review the chart of Troubleshooting Tips first you may not need to call for service READ THIS MANUAL Your safety...

Page 3: ...e not limited to adhesives solvents paint thinners etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammable or combustible materials anywhere near...

Page 4: ...achieved with the Bath USC 117 or USC2 117 remote control Only qualified service personnel should perform this adjustment Only factory authorized remote control s should be used Notice When this water...

Page 5: ...e or LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level Before attempting to light the water heater make sure to...

Page 6: ...ntial water heaters of a capacity greater than 52 gallons or tankless style consult the local building jurisdiction code for acceptable bracing procedures Have the installer show you the location of t...

Page 7: ...which may result in severe burns death or property damage The water heater must be located so it is not subject to physical damage for example by moving vehicles area flooding etc The water heater sh...

Page 8: ...n How to Obtain Service Assistance Do not destroy this manual Please read carefully and keep in a safe place for future reference Recognize this symbol as an indication of Important Safety Information...

Page 9: ...level 12 inches 30 cm above anticipated snow level B Clearance to window or door that may be opened 6 inches 15 cm for appliances 10 000 Btuh 3 kW 12 inches 30 cm for appliances 10 000 Btuh 3kW and 10...

Page 10: ...accidental contact with people and pets Install outdoor water heater such that air inlet and flue outlet is above anticipated snow level 1 8 m If soffit vent is too close block off and install new ven...

Page 11: ...of 0 66 gpm 2 5 lpm A water pressure of 40 psi 276 kPa is required to achieve maximum flow rate To maintain proper performance ensure sufficient water supply pressure The Required Water Pressure Min O...

Page 12: ...heck Valve between the water heater and the water shutoff valve see the top left diagram The following should be addressed in regards to the HOT WATER OUTLET Connections between the water heater and p...

Page 13: ...e relief valve and discharge line The end of the discharge line should not be threaded or concealed and should be protected from freezing No valve of any type restriction or reducer coupling should be...

Page 14: ...of the National Fuel Gas Code In Canada the latest edition of CSA B149 1 Natural Gas and Propane installation code Manual Gas Supply Line Shutoff Manual Gas Appliance Shutoff Union Sediment Trap Cap...

Page 15: ...nd electrical grounding must comply with local codes or in the absence of local codes with the latest edition of the National Electrical Code ANSI NFPA 70 or in Canada Canadian Electrical Code CSA C22...

Page 16: ...r the base plate Ensure the projections in the base plate fit into the housings in the remote control Fix the control to the base plate at the bottom of the remote control using the screw provided Pro...

Page 17: ...NTMODELONLY POURMOD LE VENTDIRECTSEULEMENT SW3 SW2 SW1 U 2 1 S 1 3 2 W W 12 3 4 I J H F W W 2 3 4 1 B R Y O W BR BK 1 2 3 4 5 6 7 8 R Y O W BR BK 1 2 3 4 5 6 7 8 C 9 R BR BK BK W BK W 1 2 3 4 Y W BK 1...

Page 18: ...ufacturer s instructions Outdoor Models Discharge Line To Suitable Drain To Hot Water Faucet s Relief Valve Union Drain Valve 6 15 cm Air Gap Manual Gas Appliance Shut off supplied Flue Terminal Trap...

Page 19: ...heat loss encountered with storage tank heaters This water heater does not store water making an insulation blanket unnecessary The manufacturer s warranty does not cover any damage or defect caused...

Page 20: ...nd piping Water connections tight and free of leaks Water filter is clean and in place Materials used are as instructed in this manual Water pipes are insulated and protected from freezing C Gas Suppl...

Page 21: ...s label 2 Turn off all electric power to the appliance 3 Do not attempt to light the burner by hand 4 Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the OFF position 5 Wait...

Page 22: ...s to the water heater If there is any difficulty in understanding or following the Operating Instructions or the Care and Cleaning section it is recommended that a qualified person or serviceman perfo...

Page 23: ...above 112 F 44 C when a hot water faucet is in the open position Notice The factory setting allows operating temperatures between 100 F 38 C and 120 F 49 C Temperatures of 85 F 29 C and up to140 F 60...

Page 24: ...ater heater discharges periodically this may be due to a problem in the water system Contact the water supplier or your plumbing contractor on how to correct this DO NOT plug the relief valve outlet R...

Page 25: ...NOT scrub the appliance with a brush Use only mild soapy water other cleaners may damage the surface of the water heater DO NOT remove any label including the rating plate while cleaning or servicing...

Page 26: ...ter may be exposed to freezing conditions even for a short period of time be sure to drain all water from the unit as instructed above Exposure to freezing conditions can occur from down draft of vent...

Page 27: ...Valve Malfunctions if applicable Check and replace if necessary Error code displayed on remote control See instructions for Error Code and if required contact a dealer for service Not enough water de...

Page 28: ...in Gas Line Power supply not grounded Low inlet gas pressure due to improper sizing Wrong gas type Open the Gas shutoff valve fully Contact gas utility company Fill up LP Gas container or replace with...

Page 29: ...as noted below and number of parts desired CAUTION For your safety DO NOT attempt repair of electrical wiring gas piping burners vent connectors or other safety devices Refer repairs to qualified serv...

Page 30: ...econds Number 120 on the display of the remote control will begin to blink While the number is blinking push the UP arrow temperature adjustment button and the Down arrow temperature adjustment button...

Page 31: ...ay not function properly NOTICE If the water heater is installed less than 3 280 feet 1 000m no action is required How to adjust the DIP switch on the PCB for high altitude installation Check the alti...

Page 32: ...act the Manufacturer s National Service Department at the following address 1241 Carwood Court Montgomery AL 36117 Phone 1 800 432 8373 When contacting the manufacturer the following information will...

Reviews: