background image

1- Terminal

2- Read Voltage value

3- Setting of regulator Voltage

4- DFM

SIG Terminal

Sample plugs:

Testing SIG terminal regulators

Main screen SIG

12.6

Vread

Vset

DFM

+

DFM

-

12.6

l
l
l

l

l

l

Speed up the alternator to about 1000 RPM

Wait for the WAI1000 to connect to the regulator

When information about the regulator shows up you can control

the Voltage by rotating the control knob

When changing the Vset value Vread should decrease or

increase accordingly

If the regulator supports DFM while Vset changes the value

should also change

Pressing the control knob makes the WAI1000 go back to the

protocol selection screen 

FR    SIG    A

 

 

WAI1000 Tester

 Quick Start Manual

Summary of Contents for WAI1000

Page 1: ...Quick Start Manual www waiglobal com ...

Page 2: ...this technical instruction manual are based on the latest information available at the time of publication WAI Global reserve the right to make changes at any time without obligation to notify any person or organization of such revisions or changes Copyright No part of this manual may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photoc...

Page 3: ...ly 12V input 4 B terminal power supply 5 COM terminal control line for ECU protocols 6 DFM monitor positive field order 7 DFM monitor negative field order Turn knob clockwise or counter clockwise to switch between options 1 2 Confirm your selection by pushing the knob 3 WAI1000TesterQuickStartManual EN ...

Page 4: ... Ford Volvo Mazda DFM Various Steps 1 Connect red clamp 3 to b terminal of alternator or to the terminal of battery 2 Connect black clamp 4 to ground alternator housing or minus terminal of battery 3 Connect green wire 5 to the com lin bss sig rc rlo c d terminal 4 Connect blue wire to the dfm 6 or dfm 7 fr 6 7 Note green wire is always used to control alternator After connecting the WAI1000 to a ...

Page 5: ...regulator Voltage 7 DFM 1 Protocol 2 Regulator ID 3 Errors T Temperature M Mechanical E Electrical 4 Read Voltage value 5 Setting of regulator Voltage 6 DFM l l l l l l Speed up the alternator to about 1000 RPM Wait for the WAI1000 to connect to the regulator When information about the regulator shows up you can control the Voltage by rotating the control knob When changing the Vset value Vread sh...

Page 6: ...ow L will not be accurate PWM type Dial knob clockwise Counter clockwise to set Vset value Vread should increase or decrease accordingly If the regulator supports DFM whilst Vset changes the value should also change Pressing the control knob makes the WAI1000 go back to the protocol selection screen 12 6 Vread Vset DFM DFM 12 6 C S L G S L F C FR C FR L IG C FR L IG There are two types of C termin...

Page 7: ... for the WAI1000 to connect to the regulator When information about the regulator shows up you can control the Voltage by rotating the control knob When changing the Vset value Vread should decrease or increase accordingly If the regulator supports DFM while Vset changes the value should also change Pressing the control knob makes the WAI1000 go back to the protocol selection screen L M IG RLO WAI...

Page 8: ...lternator to about 1000 RPM Wait for the WAI1000 to connect to the regulator When information about the regulator shows up you can control the Voltage by rotating the control knob When changing the Vset value Vread should decrease or increase accordingly Pressing the control knob makes the WAI1000 go back to the protocol selection screen P D1 P1 D WAI1000TesterQuickStartManual ...

Page 9: ...ait for the WAI1000 to connect to the regulator When information about the regulator shows up you can control the Voltage by rotating the control knob When changing the Vset value Vread should decrease or increase accordingly If the regulator supports DFM while Vset changes the value should also change Pressing the control knob makes the WAI1000 go back to the protocol selection screen F L RVC DFM...

Page 10: ...ait for the WAI1000 to connect to the regulator When information about the regulator shows up you can control the Voltage by rotating the control knob When changing the Vset value Vread should decrease or increase accordingly If the regulator supports DFM while Vset changes the value should also change Pressing the control knob makes the WAI1000 go back to the protocol selection screen FR SIG A WA...

Page 11: ...controlling alternator COM DFM BSS DFM DFM L L DFM 1 Terminal 2 Read Voltage value 3 Setting of regulator Voltage 4 DFM DFMMonitor Sample plugs Testing DFM terminal regulators Main screen DFM 12 6 Vread Vset DFM DFM 12 6 l WAI1000TesterQuickStartManual EN ...

Page 12: ...416 740 5348 WAI Canada 4711 Boul Couture Montréal St Léonard Québec H1R 3H7 Toll Free 1 800 661 2962 Fax 514 328 1535 WAI United Kingdom Christie Place Durban Road Bognor Regis West Sussex PO22 9RT Phone 44 0 1243 833 420 Fax 44 0 1243 833 421 WAI Europe Klappolder 225 2665 MR Bleiswijk The Netherlands Phone 31 0 10 524 1980 Fax 31 0 10 524 1981 WAI Brazil Av Coronel Marcos Konder 1207 Sala 7088 ...

Reviews: