On principle, the configuration of a central operation (e.g. central switch, timer)
should take place according to the following scheme.
L / N / PE
230 V
AC
24 V
DC
Central Connection Standard
Central Control
GND
up
down
Figure 11: Wiring of the Winsta sunblind boxes for conventional 24 V control
In central operation without voltage monitoring, 24V levels are evaluated as a
control signal.
Heed the line dimensioning!
For the wiring of a system with central control, make sure that the dimensioning
(length and cross-section) of the control line is made according to the boxes
connected.
Setting of the DIP Switches
Switch 4 of DIP Module 2 must be de-activated for operation without voltage
monitoring.