Manual 

 

 

 

WAGO-PERSPECTO 762

PERSPECTO VP, Visu-Panel

762-2035, -2057, -2104, -2121, -2150

Version 1.0.0 

 

Summary of Contents for PERSPECTO VP Visu-Panel 762

Page 1: ...Manual WAGO PERSPECTO 762 PERSPECTO VP Visu Panel 762 2035 2057 2104 2121 2150 Version 1 0 0 ...

Page 2: ...8 87 5 55 Fax 49 0 571 8 87 85 55 E mail support wago com Every conceivable measure has been taken to ensure the accuracy and completeness of this documentation However as errors can never be fully excluded we always appreciate any information or suggestions for improving the documentation E mail documentation wago com We wish to point out that the software and hardware terms as well as the tradem...

Page 3: ...ERSPECTO VP Visu Panel 13 3 2 View 14 3 3 Connections 15 3 4 Technical data 16 4 Assembly 20 4 1 Connect devices 21 4 1 1 X1 Supply Voltage 22 4 1 2 X2 Serial Interface RS 485 RS232 23 4 1 3 X3 Serial Interface RS232 24 4 1 4 X4 CAN 1 Interface 25 4 1 5 X5 CAN 0 Interface 26 4 1 6 X6 Ethernet Interface 27 4 1 7 X8 X9 USB Interface 28 4 2 Battery Compartment 29 4 3 Service switch 30 5 Commissioning...

Page 4: ...2104 2121 2150 PERSPECTO VP Visu Panel 5 3 1 5 The HTTP Tab 41 5 3 1 6 The RAS Tab 42 5 3 1 7 The Backup Restore Tab 43 5 3 1 8 The Advanced Tab 45 5 4 Saving the Configuration 45 6 Maintenance 46 List of Figures 47 List of Tables 48 Manual Version 1 0 0 ...

Page 5: ... documentation to any subsequent owner or user of the device In addition ensure that any supplement to this documentation is included if necessary 1 1 Scope of Validity This documentation applies to PERSPECTO VP Visu Panel 762 2035 2057 2104 2121 2150 1 2 Copyright This documentation including all figures and illustrations is copyright protected Any further use of this documentation by third parti...

Page 6: ...te risk potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Personal Injury Indicates a low risk potentially hazardous situation which if not avoided may result in minor or moderate injury NOTICE Damage to Property Indicates a potentially hazardous situation which if not avoided may result in damage to property NOTICE Damage to Property Caused by El...

Page 7: ...out this Documentation 7 762 2035 2057 2104 2121 2150 PERSPECTO VP Visu Panel Information Additional Information Refers to additional information which is not an integral part of this documentation e g the Internet Manual Version 1 0 0 ...

Page 8: ...talics e g C Programme WAGO IO CHECK Menu Menu options are displayed in bold e g Save Ein Größer als Zeichen zwischen zwei Namen bedeutet die Auswahl eines Menüpunktes aus einem Menü z B Datei Neu Input Designation of input or optional fields are displayed in bold e g Start of measurement range Value Input or selective values are displayed in inverted commas e g Enter the value 4 mA under Start of...

Page 9: ...rease the efficiency of technical progress WAGO Kontakttechnik GmbH Co KG owns all rights arising from the granting of patents or from the legal protection of utility patents Third party products are always mentioned without any reference to patent rights Thus the existence of such rights cannot be excluded 2 1 2 Personnel Qualification All sequences implemented on Series 762 devices may only be c...

Page 10: ... This is a class A device This device can cause radio interference in residential areas In this case the operator may be required to take appropriate measures 2 1 4 Technical Condition of Specified Devices For each individual application the devices are supplied from the factory with a dedicated hardware and software configuration Changes in hardware software and firmware are permitted exclusively...

Page 11: ... by means of specific keys or tools DANGER Adhere to the accident prevention provisions For assembly start up maintenance and troubleshooting adhere to the specific accident prevention provisions which apply to your system e g BGV A 3 Electrical Installations and Equipment DANGER Ensure a standard connection To minimize any hazardous situations resulting in personal injury or to avoid failures in ...

Page 12: ...aterials are imperative for handling devices NOTICE Cleaning only with permitted materials Clean soiled contacts using oil free compressed air or with ethyl alcohol and leather cloths NOTICE Do not use any contact spray Do no use any contact spray the spray may impair contact area functionality in connection with contamination NOTICE Avoid electrostatic discharge The devices are equipped with elec...

Page 13: ...T development environment is used to program the panels and controllers 3 1 PERSPECTO VP Visu Panel The Visu Panel contains a HMI runtime for operation and visualization of WAGO I O system controllers A Web server for connection PERSPECTO WP Web panels is integrated in addition to the HMI runtime The WEB visualization of the Web server can also be displayed by other Internet enabled terminals such...

Page 14: ... PERSPECTO 762 762 2035 2057 2104 2121 2150 PERSPECTO VP Visu Panel 3 2 View Figure 1 Front view of the 5 7 panel Table 3 Legend for View figure No Description 1 PERSPECTO control panel 2 Touchscreen display Manual Version 1 0 0 ...

Page 15: ...the Connections figure The connection designation is the same for all devices Table 4 Legend for Connections figure No Description X1 Connection for 24VDC power supply X2 RS 232 or RS 485 serial interface as D sub 9 connector X3 RS 232 serial interface as D sub 9 connector X4 CAN Bus 1 CANopen interface as D sub 9 connector X5 CAN Bus 0 CANopen interface as RJ45 jack X6 Ethernet interface as RJ45 ...

Page 16: ...lay lighting 50 000 hrs 50 000 hrs Operating system Windows CE 6 0 Windows CE 6 0 Processor 32 bit ARM9 200 MHz 32 bit ARM9 200 MHz RAM Flash SRAM 64 MB 64 MB 1 MB 64 MB 64 MB 1 MB Memory expansion MicroSD max 2 GB SD card max 2 GB Panel Touch analog resistive Touch analog resistive Light transmission typ 80 typ 75 Durability 100 000 activations with touch pen 100 000 activations with touch pen In...

Page 17: ...stic Plastic Dimensions W x H x L 96 x 96 x 29 mm 208 x 150 x 42 mm Panel cutout W x H 91 x 91 mm 198 x 140 mm Fixing means 2 x clamping elements 4 x clamping elements Voltage supply 24VDC 18 30 v 24VDC 18 30 v Max input current 24 V 250 mA 250 mA Operating power 8 12 W 8 12 W Operating temperature 0 C 50 C 0 C 50 C Storage temperature 10 C 60 C 10 C 60 C Relative humidity without condensation 10 ...

Page 18: ...tel Atom N270 1 6 GHz RAM Flash SRAM 64 MB 32 MB 1 MB 64 MB 32 MB 1 MB 256 MB 128 MB Memory expansion CF card max 2 GB CF card max 2 GB CF card max 2 GB Panel Touch analog resistive Touch analog resistive Touch analog resistive Light transmission typ 80 typ 80 typ 80 Durability 10 million activations with finger 10 million activations with finger 35 million activations with finger Interfaces USB 2...

Page 19: ...x L 284 x 222 x 46 mm 330 x 268 x 47 mm 398 x 306 x 77 mm Panel cutout W x H 268 x 206 mm 312 x 250 mm 383 x 291 mm Fixing means 6 x clamping elements 6 x clamping elements 6 x clamping elements Voltage supply 24VDC 18 30 V 24VDC 18 30 V 24VDC 18 30 V Max input current 24 V 500 mA 500 mA 1300 mA Operating power 10 18 W 10 18 W 28 35 W Operating temperature 0 C 50 C 0 C 50 C 0 C 45 C Storage temper...

Page 20: ...chnical data apply to the recommended mounting position If the panel is mounted in a position different than recommended cooling can be affected Contact WAGO Service for more information The PERSPECTO Series panels are used in the panel cutout provided and bolted down with the included clamping elements from behind note the following installation diagram Figure 3 Installation of the clamping eleme...

Page 21: ... as a communication interface to other devices The CAN interface with electrical isolation is used as a communication interface to other CAN devices The CANopen slave and customer custom protocols can be used The Ethernet interface is used for connection to a LAN The USB master interfaces are used for connecting to a keyboard mouse or USB stick Because there are a large number of USB devices on th...

Page 22: ...nection for the device power supply More information about the power supply and and power consumption is available in the Technical Data section Figure 4 X1 Supply Voltage Table 6 X1 pin assignment Pin Assignment Function 1 24 V DC Supply Voltage 2 0 V GND Reference potential GND 3 PE Ground conductor Manual Version 1 0 0 ...

Page 23: ...the device It is generally used for communication service devices modem operation etc The connected data cable must be shielded Figure 5 X2 serial interface RS 485 RS232 Table 7 X2 pin assignment Pin Assignment Function 1 Y Tx RS 485 2 RxD Receive Data for RS 232 3 TxD Transmit Data for RS 232 4 Z Tx RS 485 5 GND 5V Signal Ground 6 R Terminating resistor 7 B Rx RS 485 8 A Rx RS 485 9 R Terminating...

Page 24: ...ed data cable must be shielded A null modem connection is used to connect to another device with RS 232 interface A 1 1 connecting cable is used to connect to a modem Figure 6 X3 serial interface RS232 Table 8 X2 pin assignment Pin Assignment Function 1 DCD Data carrier detect 2 RxD Receive Data for RS 232 3 TxD Transmit Data for RS 232 4 DTR Data Terminal ready 5 GND 5V Signal Ground 6 DSR Data s...

Page 25: ...inating resistor that can be switched on by relay is integrated in the device in accordance with ISO11898 More information is available from our description of the E5014 fieldbus systems The connected data cable must be shielded Figure 7 X4 CAN 1 interface D Sub 9 Table 9 X4 pin assignment Pin Assignment Function 1 open 2 B_LB CAN data low dominant 3 GND5V ext2 Signal Ground extern 2 4 open 5 GND5...

Page 26: ...e with ISO 11898 A terminating resistor that can be switched on by relay is integrated in the device in accordance with ISO11898 More information is available from our description of the E5014 fieldbus systems The connected data cable must be shielded Figure 8 X5 CAN 0 interface RJ 45 Table 10 X5 pin assignment Pin Assignment Function 1 B_LA CAN data low dominant 2 B_HA CAN data high dominant 3 GN...

Page 27: ...an 2 devices in a network then they must be connected to each other by a HUB or SWITCH A 1 1 cable is used here If there are only 2 devices in a network the a crossover cable can be used Figure 9 X6 Ethernet RJ 45 Table 11 X6 pin assignment Pin Assignment Function 1 TX Transmit Data 2 TX Transmit Data 3 RX Receive Data 4 n c 5 n c 6 RX Receive Data 7 n c 8 n c LED D1 Status LED Full Duplex LED D2 ...

Page 28: ...face type A The following table and illustration provide information on the pin assignment of the interfaces The interface connection meets USB specification 1 1 Figure 10 X8 X9 USB interface Table 12 X8 X9 pin assignment Pin Assignment Function 1 USB_VCC1 USB 5VDC 2 USB_N1 USB data line N1 3 USB_P1 USB data line P1 4 USB_GND USB GND Manual Version 1 0 0 ...

Page 29: ...change the lithium battery during a power failure make sure that you have the new battery ready to hand For a certain time a gold cap capacitor provides the required power The data of the volatile memory SRAM is therefore preserved during a battery exchange At room temperature the battery has a life span of about one year It is not possible to check the capacity of the battery via the CoDeSys func...

Page 30: ...2150 PERSPECTO VP Visu Panel 4 3 Service switch The service switch on the back of the device is used to call up the Windows CD desktop The WAGO Control Center can be launched for example to configure the device Figure 12 Service switch Manual Version 1 0 0 ...

Page 31: ...m launching automatically the touchscreen must be touched within a window of three seconds default setting after the boot self test phase The service switch on the back of the device can be used to launch the Windows CE desktop at any time The WAGO Control Center can be used to change the start behavior of the device Note Time window for launching the Windows CD desktop The WAGO Control Center can...

Page 32: ...n der IP Adresse section The device can either draw its IP address from a DHCP server on the network or the device can be assigned a fixed IP address The current IP address can be queried by double clicking on the network icon in the system tray in the task bar Note DHCP fixed IP address The device must be connected to a network to change the IP address from DHCP to a fixed IP address Note Subnet ...

Page 33: ...sed to set the IP address Call up the WAGO Control Center from the Start menu Start Settings Control Panel WAGO Control Center 1 Click the Advanced tab and then on the LAN button 2 In the DM9102 Fast Ethernet Adapter Settings click on the IP Address tab 3 Enter the desired IP address and click OK to confirm Figure 13 IP address Manual Version 1 0 0 ...

Page 34: ...r cable to connect between the panel and configuring PC directly it is recommended that both devices have fixed IP addresses with an open address in the range 192 168 1 xxx In this case the subnet mask is automatically set to 255 255 255 0 There is no default gateway Note IP Address The devices must be set to different IP addresses Manual Version 1 0 0 ...

Page 35: ...d to configure the device Settings for the Autostart programs uses FTP HTTP and RAS access can be made General device settings can also be checked and modified 5 3 1 Starting the WAGO Control Center The WAGO Control Center is lunched from the Start menu Start Settings Control Panel WAGO Control Center Figure 14 WAGO Control Center Manual Version 1 0 0 ...

Page 36: ...the device is found here This information is important for example for support cases General Watchdog available from V1 61 A watchdog can be configured here which can restart the device if it crashes after a set time Don t start Windows CE Shell If the checkbox is enabled the Windows CE desktop can no longer be launced The task bar is no longer displayed Manual Version 1 0 0 ...

Page 37: ...s when the input field is pressed No values can be entered Note Service switch If the checkbox was accidentally enabled the Windows CE desktop can be launched again by pressing the Service switch on the back of the device and the checkbox can be disabled Simple Network Time protocol If there is an Internet connection the system clock of the device can be synchronized via an SNTP server Manual Vers...

Page 38: ...art Applications Tab You can enter programs here that should launch automatically after booting The HMI runtime is entered here by default The time window for launching the programs after the boot and self test phase of the device can also be set here Figure 16 Autostart Applications tab Manual Version 1 0 0 ...

Page 39: ...y The user starts downwards from this menu The use cannot get to higher level directories Virtual Roots A directory from another protected tree for example can be put in the user s home directory By doing so you gain access to this and subsequent directories Note Access Rights If no home directory is set for a user the user gets FULL ACCESS to the panel despite disabled write access Enter at least...

Page 40: ... 2035 2057 2104 2121 2150 PERSPECTO VP Visu Panel 5 3 1 4 The FTP Tab You can configure the FTP server of the device here More information about creating users is available in the The Users Tab section Figure 18 FTP tab Manual Version 1 0 0 ...

Page 41: ...ure the Web server of the device here Figure 19 HTTP tab Application example An httptest directory with the test alias was created on the flash disk A Web page index htm was created in this directory The page can be used in a Web browser to access the following address http IP address of the device test Manual Version 1 0 0 ...

Page 42: ...ervice for remote access to a Windows CE device Figure 20 RAS tab Both RAS functions server and client are supported The connection between a RAS client and the RAS server can be established via a modem VPM or direct connection For more information about the Remote Access Service RAS of the device please contact WAGO Support Manual Version 1 0 0 ...

Page 43: ...go backup registry reg HKEY_LOCAL_MACHINE Drivers BuiltIn BackLight MaxIntensity The section devices the registry entries to be saved The path indicates where the registry entries shall be saved The registry entries to be saved are listed there SRAM Destination path filename or automatically sram bin Memory Stick wago backup sram The path indicates where the SRAM content shall be saved FILES defau...

Page 44: ...tore cfg and entries on the target data carrier The Restore button is used to restore the parameters defined in the backup_restore cfg and entries on the device Note Create backup It is recommended that you create a backup after commissioning the device and to keep the backup in a safe place Note Operating system update There is no operating system update for the device Manual Version 1 0 0 ...

Page 45: ...lly self explanatory Figure 22 Advanced tab 5 4 Saving the Configuration After configuring the panel the settings must be permanently saved in the registry Call up the following utility program Start Programs Utilities Save Registry Note Fail safe saving of the configuration If the settings are not saved as described they are lost when the device is restarted Manual Version 1 0 0 ...

Page 46: ...ss If the device is switched off when the battery has failed or has reached its capacity without replacing the battery any settings not saved are lost Replace the battery as follows 1 Make sure that the device has been on for at least 10 minutes before replacing the battery allowing the buffer capacitors to load 2 Switch off the power supply 3 Remove the buffer battery and install a new one 4 Rest...

Page 47: ...6 X3 serial interface RS232 24 Figure 7 X4 CAN 1 interface D Sub 9 25 Figure 8 X5 CAN 0 interface RJ 45 26 Figure 9 X6 Ethernet RJ 45 27 Figure 10 X8 X9 USB interface 28 Figure 11 Battery compartment 29 Figure 12 Service switch 30 Figure 13 IP address 33 Figure 14 WAGO Control Center 35 Figure 15 The General tab 36 Figure 16 Autostart Applications tab 38 Figure 17 Users tab 39 Figure 18 FTP tab 40...

Page 48: ... Conventions 8 Table 3 Legend for View figure 14 Table 4 Legend for Connections figure 15 Table 5 Technical data 16 Table 6 X1 pin assignment 22 Table 7 X2 pin assignment 23 Table 8 X2 pin assignment 24 Table 9 X4 pin assignment 25 Table 10 X5 pin assignment 26 Table 11 X6 pin assignment 27 Table 12 X8 X9 pin assignment 28 Manual Version 1 0 0 ...

Page 49: ...WAGO PERSPECTO 762 List of Tables 49 762 2035 2057 2104 2121 2150 PERSPECTO VP Visu Panel Manual Version 1 0 0 ...

Page 50: ...WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastraße 27 D 32423 Minden Phone 05 71 8 87 0 Fax 05 71 8 87 1 69 E mail info wago com Internet http www wago com ...