Overview of Error Blink Codes
•
239
Auxiliary
Commands
WAGO-I/O-SYSTEM 750
I/O Modules
3.5 Configuration Variables
Address
Configuration
variable
Dec. Hex.
Data
type
Default Range
Description
User_Conf_Id
0
0x00
UINT16 0
0 ... 50000
The user can freely assign data set
numbers. However, numbers greater
then 50000 are reserved.
ConfVersion
2
0x02
UINT8 4
0 ... 254
Configuration version number
Switching of applications. The
appropriate process image is activated
when a new application is selected.
0: Reserved
1: Positioning
controller
Application_
Selector
3
0x03
UINT8 1
0 ... 2
2: Velocity
control
Frequency output
Freq_Div
4
0x04
UINT16 200
4 ... 65535
Sets the prescaler for maximum velocity
Acc_Fact
6
0x06
UINT16 80
1 ... 65535
Sets factor for maximum acceleration
Current
14
0x0E
UINT8 10
0 ... 10
Motor rated current in [0.1 A]
Current_Ratio_
StandStill
15
0x0F
UINT8 33
0 ... 150
Current factor at standstill in [%], based
on motor rated current "Current"
Current_Ratio_
RampUp
16
0x10
UINT8 120
0 ... 150
Current factor for ramp-up in [%], based
on motor rated current "Current"
Current_Ratio_
Drive
17
0x11
UINT8 50
0 ... 150
Current factor for drive in [%], based on
motor rated current "Current"
Current_Ratio_
RampDown
18
0x12
UINT8 90
0 ... 150
Current factor for ramp-down in [%],
based on motor rated current "Current"