40
Connect Devices
WAGO-I/O-SYSTEM 757
757-801 Bluetooth® Module RS-232
Manual
1.0.0
Pos : 54 /All e Seri en (Allgemei ne Module)/Ü berschrif ten f ür alle Serien/Ansc hließ en/ Ger ät e ansc hließen - Ü bers chrift 1 @ 3\ mod_1234172889468_21.doc x @ 27460 @ 1 @ 1
6
Connect Devices
Pos : 55.1 /Serie 757 (Funkadapt er I P67)/ Wichtige Erläut erungen/Sic herheits- und sonstige Hinweis e/ War nung/ Warnung: 757- 801 Spezi elle Anf orderungen an di e Spannungs vers orgung i m Bezug auf U L 508 @ 14\ mod_1363701956244_21. doc x @ 115073 @ @ 1
Special requirements for power supply within the scope of application of
UL 508!
For UL 508 approval, the device must be operated using a 24 V Class 2 power
supply unit or a Class 2 transformer in compliance with UL 1310 or UL 1585.
Pos : 55.2 /Serie 757 (Funkadapt er I P67)/ Wichtige Erläut erungen/Sic herheits- und sonstige Hinweis e/Achtung/Acht ung: Hi nweis für offene Ans chl üss e 757-801 @ 14\ mod_1363346830510_21.doc x @ 114562 @ @ 1
Pre-assemble free cable ends!
The end of the
Bluetooth
®
Module RS-232 IP67’s connection cable is free. If
cable ends have not been pre-assembled, liquid or dirt can penetrate into the
Bluetooth
®
Module RS-232 IP67 and ruin it. Pre-assemble the connection cable
according the environment or use the connection cable in an environment
complying with IPX0 protection class!
Pos : 55.3 /Serie 757 (Funkadapt er I P67)/ Wichtige Erläut erungen/Sic herheits- und sonstige Hinweis e/Achtung/Acht ung: Länge der Z uleit ung der Spannungs versorgung begrenz en @ 14\ mod_1359011579212_21. doc x @ 109757 @ @ 1
Limit the length of the power supply feed line!
The length of the feed line between the power supply unit and the product
connecting cable is limited to ensure proper power supply. Supply voltage
filtering must be provided if the length of the power supply feed line exceeds 3 m.
Pos : 55.4 /Serie 757 (Funkadapt er I P67)/ Ansc hließen/ Ans chl uss kabel vor ber eiten @ 14\ mod_1361258743327_21. doc x @ 112230 @ 22 @ 1
6.1
Preparation of Connecting Cable
First prepare the open end of the connecting cable for installation:
1.
Remove the outer insulation.
2.
Push back the shield mesh.
3.
Remove any unneeded shield foil.
4.
Separate the 6 inner wires.
5.
Shorten the inner (filling) conductor.
6.
Prepare the 6 inner wires.
Figure 14: Assembled connecting cable