WAGO-I/O-SYSTEM 750 XTR
Use in Hazardous Environments
45
750-468/040-000 4AI 0-10V DC S.E. /XTR
Manual
Version 1.3.0
Pos : 65.16 / Serie 750 ( WAG O-I/ O-SYST EM)/Ei ns atz i n Ex-Bereic hen/ Beispi elbedruc kung und Text detail C EC_2017 @ 29 \ mod_1497865583297_21. doc x @ 424736 @ @ 1
Figure 19: Text Detail
– Marking Example for Approved Ex i I/O Modules According to CEC 18
attachment J
Table 26: Description of Marking Example for Approved Ex i I/O Modules According to CEC 18
attachment J
Marking
Description
Dust
Ex
Explosion protection mark
nA
Type of protection
[ia IIIC]
Type of protection and equipment protection
level (EPL): Associated apparatus with intrinsic
safety circuits for use in Zone 20
IIC
Group
T4
Temperature class
Gc
Equipment protection level (EPL)
X
Symbol used to denote specific conditions of use
Gases
Ex
Explosion protection mark
nA
Type of protection
[ia Ga]
Type of protection and equipment protection
level (EPL): Associated apparatus with intrinsic
safety circuits for use in Zone 0
IIC
Group
T4
Temperature class
Gc
Equipment protection level (EPL)
X
Symbol used to denote specific conditions of use
Pos : 65.17 /D okument ati on allgemei n/Gli ederungsel ement e/---Seit enwec hs el--- @ 3\ mod_1221108045078_0. doc x @ 21810 @ @ 1