WAGO-I/O-System 750
Appendix 169
750-370 PROFINET IO Fieldbus Coupler
Manual
Version 2.0.0
14.1.6.8 AS-Interface Master Modules
There is one module type for the AS-Interface master modules.
Table 93: Module Types – AS-Interface Master Modules
Module type
Description
Substitute I/O modules
ASi-Master
AS-Interface-Master
75x-655
With the AS-Interface Master, the provider and consumer status (IOPS, IOCS) of
the input or output information are exchanged between the IO controller and IO
device in both directions.
There are the following submodule types for the AS-Interface master modules.
Table 94: Submodule Types and Data Lengths – AS-Interface Master Modules
PNIO module type
Process data length [byte]
Telegram
allocation [byte]
PNIO submodule type
Data type
Input (I-PI) Output (O-PI) Input
Output
ASi-Master
ASi-Master 12 byte I/O
{Unsigned8,
Unsigned8,
Unsigned8[10]}
12
12
14
14
ASi-Master 20 byte I/O
{Unsigned8,
Unsigned8,
Unsigned8[18]}
20
20
22
22
ASi-Master 24 byte I/O
{Unsigned8,
Unsigned8,
Unsigned8[22]}
24
24
26
26
ASi-Master 32 byte I/O
{Unsigned8,
Unsigned8,
Unsigned8[30]}
32
32
34
34
ASi-Master 40 byte I/O
{Unsigned8,
Unsigned8,
Unsigned8[38]}
40
40
42
42
ASi-Master 48 byte I/O
{Unsigned8,
Unsigned8,
Unsigned8[46]}
48
48
50
50