162 Service
WAGO-I/O-SYSTEM 750
750-325 CC-Link Fieldbus Coupler
Manual
Version 2.0.1
11
Service
11.1 Replacing 750-310 by 750-325
The 750-310 CC-Link Fieldbus Coupler with CC-Link Version V1.1 in existing
applications can be replaced by a 750-325 CC-Link Fieldbus Coupler with no
software customization.
The points listed below should be taken into account.
1.
Please note that the 750-325 with the dimensions 61.5 x 71.9 x 100 mm is
somewhat larger than the 750-310 with the dimensions 51 x 65 x 100 mm.
2.
Replace the D-sub connector for the fieldbus connection by a 231-2304
type pluggable connector. It is included in the scope of delivery.
3.
Set the rotary switch to the previous station address of the 750-310 being
used. To do this, turn the switch x1 for the unit position and the switch x10
for the tens digit of the address.
4.
Determine the number of occupied stations set and the baud rate of the
750-310 to be used.
Information
Additional information about parameters!
Details on how to determine the parameters of the 750-310 fieldbus coupler
using the corresponding setting are available in the associated
documentation for the 750-310 CC-Link Fieldbus Coupler.
The manual for the 750-310 CC-Link Fieldbus coupler is available on the
5.
Use the DIP switch to set the parameters to the respective values based on
the configuration in your master.
Table 66:750-325 to replace 750-310 (V1.1 Use) – DIP Switch Settings
Pin Value Setting
8
0
Operating mode
CC-Link V 1.1
6/7
0/0
Extended cyclic
setting
Irrelevant
4/5
x/x
Number of occupied
station addresses
Dependent on the presetting of the
750-310 fieldbus coupler to be
used.
1/2/3 x/x/x
Baud rate setting
Dependent on the presetting of the
750-310 fieldbus coupler to be
used.
11.2 Disposal