8 Cleaning and Maintenance
54
Order number 2333538 | Edition 03/2021
5. If the pump has to be emptied for maintenance work, proceed according to Chapter
50] and Chapter Emptying Pump [
Weekly
1. Check system for damage.
2. Check that the safety fixtures function properly (see Chapter Protective and Monitoring
Yearly or as required
1. In accordance with DGUV regulation 100-500, Chapters 2.29 and 2.36:
4
Have the liquid ejection devices checked by an expert (e.g. WAGNER service
technician) as required, but no later than every 12 months to ensure that they are in
safe working order.
4
For shut down devices, the examination can be suspended until the next start-up.
8.2.4 Filling with Separating Agent
NOTICE
Piston pump dry run
High wear/damage to the packings.
Paint or solvent can escape if the seals are dry.
4
Ensure that the separating agent tank is filled with sufficient separating agent.
B_03918
Pour the supplied separating agent into the intended opening.
Separating agent: order no. 9992504
Filling level: 1 cm; 0.4 inches below the cup edge.
Inclination angle of the pump
Maximum permissible inclination of pump for moving, transportation etc. after filling with
separating agent is ± 30°. The pump must be vertical during operation.
8.2.5 Condensate Drain from the AirCoat Filter Regulator
1. Frequently drain the condensate that may accumulate in the pneumatic filter.
4
Make sure the water level in the filter cup never reaches the max. level marked on
the cup.
8.2.6 Product Hoses, Pipes and Couplings
The service life of the complete hoses between product pressure generator and application
device is reduced due to environmental influences even when handled correctly.
1. Check hoses, pipes, and couplings every day and replace if necessary.
2. Before every commissioning, check all connections for leaks.