Measuring the Viscosity
1. Stir the coating material thoroughly before measuring.
2. Dip the viscosity test cup (Fig. 2. a or b) completely into the coating material.
3. Hold the test cup up and measure the time in seconds until the liquid empties out.
(Fig. 2)
This time is called "
Runout Time in Seconds
".
W 650
Viscosity Table
Spray material
Runout Time in Seconds
Large
Small
Test Cup
Test Cup
Thinner-soluble primers
25-40
30-45
Thinner-soluble varnishes
15-40
20-50
Water-soluble primers
25-40
30-45
Water-soluble varnishes
20-35
20-40
Wood preservatives, strippers, oils
undiluted
Disinfectants, plant protectants
undiluted
Automobile spray paint
20-35
20-40
Description (Fig.1)
1
Air cap
8
Air hose
2 Nozzle
9 Carrying
belt
3
Union nut
10
Air filter
4
Spray gun
11
Air screen
5
Trigger guard
12
Mains lead
6
Material volume adjustment
13
Spray gun holder
7
ON / OFF switch
14
Container
Technical Data
Max. Viscosity:
40 DIN-s
Voltage:
230 - 240 V ~
Power consumption:
350 W
Atomisation power:
95 W
Double insulation:
Sound pressure level:
80 dB (A)
Oscillation level:
< 2,5 m/s²
Air hose length:
1,8 m
Weight:
3,3 kg
Summary of Contents for W 650
Page 1: ...W 650 D GB F NL 2 Jahre GARANTIE 2 years WARRANTY 2 ans de GARANTIE 2 yaar GARANTIE ...
Page 2: ...1 1 2 7 8 3 6 5 4 13 12 9 10 11 2 a b 0209058 0050342 14 ...
Page 3: ...3 7 5 6 4 a b B A A B C 8 2 1 ...
Page 4: ...5 15 cm 10 a b 12 9 11 A B 1 Luftdüse Airnozzle Buse d air Luchtblaashulpstuk ...
Page 5: ...13 1 2 3 4 11 12 10 14 5 8 6 7 9 13 5 ...
Page 6: ...W 650 25 31 17 24 9 16 1 8 32 33 D GB F NL ...
Page 38: ......