OPERATING INSTRUCTIONS, Issue SW1201/ 2.01/ HW2.4

Wagner & Co

Solar Controller SUNGO S

Wagner & Co

Contents

1.

Technical Description . . . . . . . . . . . . . . . . . . 2

2.

General Safety Guidelines . . . . . . . . . . . . . . . 4

2.1 Installer’s Qualifications . . . . . . . . . . . . . . . . . 4
2.2 Operating Requirements . . . . . . . . . . . . . . . . 4
2.3 Installation and Operating Information . . . . . . . . 4
3.

Installation . . . . . . . . . . . . . . . . . . . . . . . . 4

3.1 Installation of the Case. . . . . . . . . . . . . . . . . . 4
3.2 Connecting Wires . . . . . . . . . . . . . . . . . . . . 5
4.

Operation . . . . . . . . . . . . . . . . . . . . . . . . . 6

4.1 Display and Buttons . . . . . . . . . . . . . . . . . . . 6
4.2 Information Menu . . . . . . . . . . . . . . . . . . . 8
4.3 Settings Menu. . . . . . . . . . . . . . . . . . . . . . 8
4.4 Manual Operation Menu. . . . . . . . . . . . . . . . 9
4.5 Special Functions Menu . . . . . . . . . . . . . . . . 9
4.6 Service – System Messages . . . . . . . . . . . . . . 10
4.7 Service – Sensor Control . . . . . . . . . . . . . . . . 10
5.

Application Examples . . . . . . . . . . . . . . . . . 11

5.1 Standard Single-Tank System . . . . . . . . . . . . . 11
5.2 SECUSOL System . . . . . . . . . . . . . . . . . . . . 12

Figure 1 Solar Controller SUNGO S.

Solar Thermal / Solar Circuit

EN-SUNGO-S_BA-0804-1122P200 · 1316BED005-30B-E

1

The benefits at a glance

  

Large

   

display

   

to

   

indicate

   

temperature,

   

balance va- 

lues and system status with clearly visible symbols for 
easy readability.

 

Easy

 

and

 

safe

 

operation

 

via

 

four

 

buttons

 

for

 

vertical

 

and 

horizontal scrolling through the menus.

 

Extensive

 

diagnostics

 

for

 

monitoring

 

system

 

functions, 

eg. sensor cutoff and monitoring of temperature differ- 
ence “

T too high”

 

Integrated

 

security

 

functions

 

such

 

as

 

collector

 

cooling, 

tank cooling, system protection and vacuum tube col- 
lector function.

 

Solar

 

charging

 

of

 

1

 

tank

 

systems 

 

Current/reset

 

values

 

3

 

temperature

 

inputs

 

Pt1000

 

1

 

output,

 

speed-controlled

Summary of Contents for SUNGO S

Page 1: ...ard Single TankSystem 11 5 2 SECUSOLSystem 12 Figure 1 Solar Controller SUNGO S Solar Thermal Solar Circuit EN SUNGO S_BA 0804 1122P200 1316BED005 30B E 1 The benefits at a glance Large display to ind...

Page 2: ...tic operation in the information menu Manual Lag Function In order to check the temperature values in the information menu even when the output channels are set manually a time lag has to be selected...

Page 3: ...mperature difference between sen sor T1 collector and sensor T2 storage cylinder The standard temperature value to activate the system pro tection is set at 135 C However it is possible to set a vari...

Page 4: ...tcheckwiththeserviceof Wagner Co The use of the control for non specified operation re sults in a lapse of the guarantee 2 3 Guidelines for Installation and Operation Because Triacs carry 230V current...

Page 5: ...nnection Mains power is connected from outside the connector via an ON OFF switch If the unit is connected with a plug to a socket the switch can be omitted The unit is designed to work with 230V AC 5...

Page 6: ...nu Information menu Temperature difference Number display for temp or sensor errors Collector temperature Reset symbol Tank temperature lower half Pump ON Pump OFF Output A1 Figure 3 Connections S a f...

Page 7: ...T2 solar Switch off difference T1 T2 solar Minimum temperature source Set point temperature difference speed control solar Solar circulation pump Maximum speed solar circulation pump SECUSOL System f...

Page 8: ...rence between collector and tank is higher than switch on difference solar circulation pump on 1 Sensor T3 tank upper half is simply a measuring sensor therefore it is not monitored by the sensor cont...

Page 9: ...0 3 SECUSOL system see SECUSOL instructions for further info 1 or 3 1 1 System Protection Off 0 On 1 Activation of system protection Cannot be activated with SECUSOL 0 or 1 1 2 System protection start...

Page 10: ...he display the line or the sensor input on the controller dT too high A fixed value of 20 K is added to the temperature difference between collector T1 and tank sensor T2 The message is displayed if a...

Page 11: ...O S P3 P2 Ta A1 T2 T3 T1 CIRCO T2 ECOplus Ttw T3 P1 T1 BWM Hot water Cold water Oil or gas boiler Heating circuit Collector field T1 Collector sensor T2 Tank sensor lower half T3 Tank sensor upper hal...

Page 12: ...oiler T1 Collector sensor T2 Tank sensor lower half T3 Tank 1 sensor upper half optional P1 Solar circulation pump P2 Heating circuit pump P3 Tank charging pump Ttw Hot water sensor heating control BW...