Operating manual Manual Powder System SPRINT XE
5 Description
24
Order number 2354920 | Edition 01/2023
– Middle LED characteristic curve, medium
– Upper LED characteristic curve, steep
33 Illuminated display [Powder quantity]
– Lights up green
– Display range: 0 – 100%
– Resolution: 3.33%
– Single LED display: Set point (high voltage and powder are deactivated)
– Bar display: Actual value (high voltage and powder are activated)
34 Illuminated display [Total air volume]
– Lights up green
– Display range: 2 – 6 m
3
/h
– Resolution: 0.2 – 0.5 m
3
/h
– Single LED display: Set point (high voltage and powder are deactivated)
– Bar display: Actual value (high voltage and powder are activated)
35 Illuminated display: [Atomizing, ionizing and Tribo air volume]
– Lights up green
– Display range: 0.1 – 4 m
3
/h
– Resolution: 0.1 – 1.0 m
3
/h
– Single LED display: Set point (high voltage and powder are deactivated)
– Bar display: Actual value (high voltage and powder are activated)
36 Push button [Powder quantity]
– To activate the function, the powder quantity is set with control dial 24 and is indicated
in LED display 19.
– Adjusting range: 1 – 100%
– Resolution: 1%
37 LED display [Powder quantity]
– Lights up yellow, when the powder quantity is selected