10 FUNCTION TEST AFTER REPAIR WORK
All functions must be checked in manual and automatic mode.
11 DISASSEMBLY AND DISPOSAL
We recommend having the WAGNER system disassembled by WAGNER or another specialist.
Before starting disassembly, all supply media (electric current, compressed air) must be
disconnected at the connection points. All powder lacquer lines must be completely
emptied and then rinsed. Lacquer residues must be disposed of in line with statutory
requirements.
Before starting disassembly, check whether the supply lines have actually been interrupted
and have been depressurized and/or de-energized if necessary.
The empty system should be thoroughly cleaned. In particular fire loads such as unused
lacquers in exhaust air pipes etc. should be removed to keep the risk of fire during
disassembly as low as possible.
We recommend reporting to the public authorities the fact that systems with mandatory
approval requirements are decommissioned.
Separate all materials encountered during disassembly as clearly as possible in line with
statutory requirements. Take appropriate actions to ensure that no dangerous substances
enter the system during disassembly. All waste produced must be separated and disposed
of in line with local requirements.
Used materials are:
– Steel
– PVC synthetic material
– cables ...