28
VERSION 01/2020
ORDER NUMBER DOC2397091
SprayPackE
5.8
CPE/CPE-S CIRCUIT BREAKERS IN HOUSING
DANGER
Danger from electric current!
Danger to life and equipment damage.
The system may only be connected by skilled electricians.
Operate according to the safety regulations, fire protection and electrotechnical
regulations.
Must be de-energized before work is commenced on active parts.
4 circuit breakers are installed to protect the supply outputs. If these trip, the rear panel of the
housing must be folded down. Then the circuit breakers can be re-activated.
P_03729
Description
Value
Description
F1
C 10A
8
Power supply for MCE controller
F2A
D 8A
2
Power supply for EPG S2, 1nd group
F2B
D 8A
3
Power supply for EPG S2, 2nd group
F3
C 16A
7
Power supply for movement devices VU and HU
Procedure:
1.
Loosen and unscrew screws (7x) on the rear panel.
2.
Carefully fold down rear panel.
3.
Switch on circuit breakers.
4.
Carefully fold the rear panel shut again and correctly screw down with the screws (7 x).