IDENTIFICATION
3.1
CE EXPLOSION PROTECTION IDENTIFICATION
As defined in the Directive 2014/34/EU the valves are suitable for use in areas subject to
explosion hazards.
Device type:
Paint valves PV 100, PV 400, GA 250PV, GA 400PV
Dosing valves DV 100, DV 400, GA 400DV
Manufacturer:
Wagner International AG
9450 Altstätten
Switzerland
CE CE mark (European
Communities)
Explosion-proof equipment
II Device class II (not mining)
2 Category 2 (zone 1)
G Ex-atmosphere gas
Ex Device corresponds to ignition protection
type
h Ignition protection for non-electrical
devices
IIC Device class (Gas) IIC
T6 Temperature class T6: maximum surface
temperature 85 °C; 185 °F
Gb Device protection level
, suitable for
use in Zone 1
X There are special instructions to ensure
safe operation. See the following Chapter
"Identification X".
3.1.1 IDENTIFICATION X
Ignition temperature of the coating product
Ensure that the ignition temperature of the coating product is above the maximum
surface temperature (85 °C; 185 °F).
Ambient temperature
Permissible ambient temperature: +5 °C to +40 °C; +41 °F to +104 °F.
Cleaning
If there are deposits on the surfaces, the device may form electrostatic charges. Flames or
sparks can form during discharge.
Remove deposits from the surfaces to maintain conductivity.
3.2
USE IN AREAS SUBJECT TO EXPLOSION HAZARDS
Safe Handling of WAGNER Spray Devices
Mechanical sparks can form if the device comes into contact with metal.
In an explosive atmosphere:
Do not knock or push the device or components and tools against steel or rusty iron.
Do not drop the device or components and tools.
National regulations
Ensure that the national explosion prevention rules and regulations are observed