Operating manual Robot powder spray gun PER-X1
8 Cleaning and Maintenance
40
Order number 2444998 | Edition 10/2022
Y
X
P_01676
3.
1.
2.
1. Guide protective wedge into wedge tool.
2. Move both parts up to stop in the opening of the electrode holder.
If it is not possible to push the wedge tool in as far as the X mark, rotate the wedge tool
a little until it can be pushed up to the mark.
The X mark must be flush with the Y end of the electrode holder.
3. The protective wedge is now correctly assembled and the wedge tool can be pulled out
of the electrode holder.
4. The protective wedge remains inserted in the electrode holder.
Prior to re-fitting, check whether the contact points on the electrode holder and in the
gun housing have been thoroughly cleaned so that the electrode tip is electrically
connected to the high-voltage generator.
5. Mount fan or round spray nozzle with the corresponding electrode holder.
8.7 CHANGING NOZZLE TYPES
NOTICE
Wrong combination of parts!
Powder can be deposited in gaps and lead to incorrect coatings due to paint carryover.
4
Only use recommended combinations (see chapter Accessories [
51])!
The standard Corona spray gun is delivered with a flat jet nozzle. The nozzle can be changed
easily, as described below.
The X1 R electrode holder is needed to change from the flat jet nozzle to the round jet
nozzle.