5.3
GROUNDING
For safety reasons, the spray gun must be properly grounded. This occurs through the
electrical cable.
Good grounding of the workpiece is also necessary for optimum powder coating.
A poorly grounded workpiece causes:
●
Dangerous electric charging of the workpiece
●
Very bad wrap around
●
Uneven coating
●
Backspraying to the spray gun, i.e. contamination
Sparks between workpiece and conveyor hooks (hangers) can occur if hooks or
other hanger parts are not completely cleaned! These sparks can cause heavy radio
frequency interference (Electro-magnetic compatibility = EMC).
WARNING
Heavy paint mist if earthing is insufficient!
Risk of poisoning
Insufficient paint application quality
Earth all unit components.
Earth the workpieces being painted.