24
GM 2800EA
"?
2MAX-
7
OPERATING MANUAL
EDITION 10/2005
PART NO. DOC0388891
Earthing scheme (example)
Minimum cable cross-section
Control unit
4 mm² (AWG 12)
Pump
4 mm² (AWG 12)
Paint container 4 mm² (AWG 12)
Conveyor
16 mm² (AWG 6)
Spraying booth 16 mm² (AWG 6)
Spraying stand 16 mm² (AWG 6)
Conveyor
Floor, antistatic
Pump
Paint container
Spraying stand
Earthing
cable
Control modul
System earth
System earth
Workpiece