64
VERSION 03/2018
ORDER NUMBER DOC 2369735
7.4.7 SET AND SAVE RECIPES
Nominal values for the high voltage (kV) and for the spray current limiter (µA) are stored in
a recipe. As standard, the following values are saved in the factory in the 3 storage places
available for recipes:
Recipe No.
Set value - high voltage in kV
Target spray current limitation in µA
R1
80
100
R2
60
100
R3
40
80
Recipes 1-3 can be selected and saved directly with the program buttons "R1", "R2" and
"R3". Once the recipe required has been called up, the individual coating parameters can
be called up and changed using the corresponding selection buttons (see Chapters
,
). When a parameter is changed, the LED on the left of the program button goes out
and indicates to the user that a parameter value has been changed.
Rejecting parameter values
To reuse the originally set values, press the program button briefly. The modified values
are not taken over.
Saving parameter values
However, if the modified values should be saved, press and hold the corresponding
program button for approx. 2 seconds until the LED beside the button starts to flash
quickly. The modified values are then saved.