15
B_05370
4
5
6
2
3
1
OPERATING MANUAL
VERSION 09/2016
ORDER NUMBER DOC 2366672
5
DESCRIPTION
5.1
COMPONENTS
1
Air outlet for gun air
4
Air inlet
2
Product outlet
5
Pump housing
3
Product inlet
6
Pressure regulator unit
The double diaphragm pump is driven with compressed air.
A pneumatic manifold alternates in supplying two diaphragms with compressed air.
Diaphragm motion is created in this manner. The product is thus sucked in and displaced
again. A series of four non-return valves prevents the liquid from fl owing back, thus
producing the suction and delivery phases in each pumping chamber, and generating the
pumping eff ect.
5.2