15
OPERATING MANUAL
VERSION 05/2017
ORDER NUMBER DOC 2357061
3.3
REMOTE CONTROL (OPTION)
The remote control (Order No. 2341153) may be used in potentially explosive areas (zone 1 and 2).
CE CE mark (European Communities)
0102 Number of the notified body
which is used by WAGNER in the
production monitoring phase
(PTB in this case)
Explosion-proof equipment
II
Device class II (not mining)
2
Category 2 device (suitable for
zone 1)
G
Ex-atmosphere gas
Ex
Electrical device corresponds to
ignition protection type
d
Ignition protection class "Flame-
proof enclosure" EN 60079-1
IIB
Device class (Gas) IIB
T6
Temperature class T6: maximum
surface temperature 85 °C; 185 °F
Gb
Device protection level
,
suitable for use in Zone 1
CML 13 ATEX 1008X
ATEX certificate number
Safety instructions
For safe operation, observe the safety data in Chapter