12. Refilling

i

The 230V unit will operate for approximately 80-100 minutes before requiring 
refilling. The water level is shown through the glass level indicator by a floating 
red bead and should not be allowed to fall below MIN level (Fig. 1, C).

• 

Switch the unit off when this level has been reached. If you require further use of the 
steamer, ensure unit is switched off and has stopped boiling.

• 

Wait for 5 minutes.  

Beware of Steam!

 The Steam is very hot - wear gloves and keep face clear.

• 

Slowly unscrew the cap, any remaining trapped steam will be released from beneath 

the cap. 

• 

Refill to the MAX water level as before (Fig. 1, C) and follow above instructions.

You must never allow the unit to boil dry. 

There is a safety thermal cut-out 

device fitted to the unit. If the unit is allowed to boil dry this will operate and 
prevent further use.

• 

Switch the unit off and allow it to cool for at least 5 minutes, refill with water and then 
switch on again - the thermal cut-out should automatically reset.

• 

If this has not reset allow a further cooling period.

13. Storage

• 

When you have finished using the unit allow any remaining water to cool and then 
empty the unit. We recommend flushing the tank out with clean water before storing.

Never leave water in the unit whilst being stored.

 

Storage Spools

• 

The supply cord and hose must be fully unwound before commencing to operate the unit.

• 

To recoil the supply cord, fit the plug into the socket-outlet on the side of the spool and 
then wind the supply cord onto the spool.

• 

To recoil the hose, place the steamplate end of the hose into the side aperture of the 
spool and then wind the hose onto the spool (Fig. 1, E).

Storage Steamplate

• 

The handle of the steamplate is shaped to locate between the frame and the tank. 

• 

Slide the steamplate into position with the handle against the tank and the thread 
towards the base (Fig. 1, F).

Summary of Contents for 2351898

Page 1: ...wagner group com D GB NL E F STEAMFORCE PRO USER GUIDE ORIGINAL BETRIEBSANLEITUNG I DK P S...

Page 2: ...2 SteamForce Pro MAX MIN A B D E C F Fig 1...

Page 3: ...3 SteamForce Pro MIN MAX 6 8 18 15 7 5 14 19 13 3 2 4 10 9 1 16 15 16 17 26 25 29 30 20 20 21 22 23 24 26 27 28 12 11 Fig 2...

Page 4: ...4045 Element Assy EU UK 2750W PS0404 12 2354105 Thermal Fuse PS0402 13 2354064 Hexagon Lock Nut M6 x 3mm PS0127 14 2382383 Cover and Shield 15 2354061 Hexagon Nut M6 x 1 0 PS0022 16 2354042 Protective...

Page 5: ...equests Please contact us via the phone number included on the back page or via our homepage www wagner group com Contents 1 Explanation of symbols used 5 2 Scope of delivery 5 3 General Safety Instru...

Page 6: ...ons Non observance of the instructions below can cause electric shock fire and or serious personal injuries a Keep your workplace clean and well lit Disorderly or unlit workplaces may result in accide...

Page 7: ...ective clothing gloves Operate the unit only with pure water without agents or additives Do not switch the unit on when empty Never point the steamplate bar at people animals at objects sensitive to t...

Page 8: ...20 stone and no more than 1 person at a time Do not permit oil grease or slippery material to accumulate on the step platform Do not allow objects to accumulate on the step platform Do not use a ladde...

Page 9: ...an extension lead rated less than 15 Amps 13 Amps as this will cause premature failure of the element which is not covered by the guarantee 9 Main Features WAGNER Steamers are professional fast actio...

Page 10: ...otect your hands with heat resistant gloves or mitts It will take between 10 and 20 minutes for the 230V unit to start producing steam depending on the temperature of the water used DO NOT leave unatt...

Page 11: ...e and prevent further use Switch the unit off and allow it to cool for at least 5 minutes refill with water and then switch on again the thermal cut out should automatically reset If this has not rese...

Page 12: ...1 1 Fill the steam wallpaper stripper with around 3 5 litres of descaling solution Switch the steam wallpaper stripper on for 10 minutes Switch the steam wallpaper stripper off again and unplug Leave...

Page 13: ...xtension lead Additives have been used Refill water See above Refresh water Steam escaping from pressure cap Blockage in hose or steamplate Build up around cap area Remove blockage Clean seating aroun...

Page 14: ...ult a qualified electrician WARNING This appliance must be earthed For your total protection it is recommended that a residual current device RCD rated at 30mA should be used in conjunction with the s...

Page 15: ...e proof of purchase of the tool through submission of the original receipt Wherever legally possible we exclude all liability for injury damage or consequential loss especially if the tool has been us...

Page 16: ...nto 28806 Alcal de Henares Madrid T 902 199 021 91 879 72 00 F 91 883 19 59 ORKLA HOUSE CARE DANMARK A S Stationsvej 13 3550 Slangerup Danmark T 45 47 33 74 00 F 45 47 33 74 01 WAGNER SPRAYTECH AUSTRA...

Reviews: