SmartAC
®
425W Power Inverter by Wagan Tech
®
11
www.wagan.com
PROBLEM: Pulsing Alarm
Reason
Solution
Input voltage below 10.5V
Keep input voltage above 10.5V
Poor or weak battery condition.
Recharge or replace battery.
Poor or loose cable connection.
Inspect terminals and tighten all
connections.
Inadequate power being delivered to
the inverter or excessive voltage drop.
Use heavier gauge DC cable.
Keep cable length as short as
possible.
DISPOSAL/RECYCLING OF INVERTER
Electronic products are known to contain materials that are toxic if improperly
disposed. Contact local authorities for disposal and recycling information.
SPECIFICATIONS
All specifications are typical at nominal line, half load and 77ºF unless otherwise
noted. Specifications are subject to change without notice.
Input
11-15V DC Input
AC Output
110-120V
Output frequency
60Hz
± 1.5Hz
Output waveform
Modified Sine Waveform
TrueRated
™
Power
(24-hour continuous)
425 Watts
Peak Surge
825
Watts