T R O UB L E SH O O T I NG

C ondition

S olution

Poor contact

Clean contact parts thoroughly

Battery v oltage is

too low

Start the engine to recharge the

battery. Replace the battery if

needed.

Shutdown on 

ov erload

Reduce the wattage of inv erter’s load

Thermal shutdown

Allow the inv erter to cool down by

reducing the load or turn it off for a

while.

Receptacle has no

power

Check the receptacle wiring.

HINT S

Adding E xtens ion C ord

If you need extension cord, we recommend the use of an

extension cord between the AC output of inv erter and

AC appliances.

You may use up to 100 ft. of high quality

extension cord.

A long cord will result in reduced output

power.

B uzz in audio s ys tem

Some stereo systems and “boom boxes” will emit a

buzzing noise from their loudspeakers when operated

from the power inv erter because the power supply in the

dev ice does not adequately filter the modified sine wav e

produced by the power inv erter. The only solution is to

use a sound system that incorporates a higher quality

power supply.

O perating a T V

Picture tubes hav e a degaussing coil that uses a high

initial surge of power to light up the screen from a “cold

start”.  If the TV does not start up on the first try, switch

ON the TV ev ery 2 - 3 seconds until the screen comes

on.

Sometimes, it may take 2-5 tries before starting.

T elevis ion interferenc e

Operating of the power inv erter can interfere with

telev ision reception on some channels. If this situation

occurs, the following steps may help to allev iate the

problem.

1.

Make sure that the chassis ground lug on the back

of the power inv erter is solidly connected to the

ground system of your v ehicles.

2.

Do not operate high power loads with the power

inv erter while watching telev ision.

3.

Make sure that the antenna feeding your telev ision

prov ides an adequate (“snow free”) signal and that

you are using good quality cable between the

antenna and the telev ision.

4.

Mov e the telev ision as far away from the power

inv erter as possible.

5.

Keep the cables between the battery and the power

inv erter as short as possible and twist them together

with about 2 to 3 twists per foot. This minimizes

radiated interference from the cables.

M A I NT E NA NC E

Very little maintenance is required to keep the inv erter

operating properly.

DE SC R I PT I O N

3000W P eak P ower

— allow you to power appliances

that require a large amount of initial (peak) power to

work (such as many TVs and motor-power equipments).

L ow B attery Alarm

— the inv erter sounds an audible

alarm then turns itself off if the source battery becomes

too low.

Auto S hutdown/R es et P rotec tion

— the inv erter

temporarily shuts itself down to protect itself from

ov erheating.

O verload/S hort C irc uit P rotec tion

— the inv erter

automatically turns itself off if the connected load is too

high or if it shorts.

F us e

— the inv erter comes with fuse/s already installed

and can be changed if it is damaged.

Dual AC O utlets

— allows you to power up to two

appliances at the same time.

4

Summary of Contents for ower Inverter

Page 1: ...User s Manual Item no 2005 R TM ...

Page 2: ...output of the inverter Powering devices by connecting from inverter to of battery terminal and connect from inverter to of battery terminal Turn ON the power switch that is located at the front of the inverter and the green LED light will light as indicator that the unit at work Insert the plug of your appliances into AC socket at the front of the inverter CAUTION DO NOT USE THE INVERTER IN A POSI...

Page 3: ...CE GREATER THAN 15 VOLT DC OPERATING THE INVERTER AND BATTERY IN OR AROUND WATER ME ASUR ING T HE AC V OL T AGE The output waveform of the AC inverter is a MODIFIED SINEWAVE To measure the AC output voltage you must use a TRUE RMS VOLTMETER SAFE T Y PR E CAUT ION Do not open the case of the inverter The high voltage inside the unit is the same type of power as your electrical outlets at home Do no...

Page 4: ... try switch ON the TV every 2 3 seconds until the screen comes on Sometimes it may take 2 5 tries before starting Televis ion interference Operating of the power inverter can interfere with television reception on some channels If this situation occurs the following steps may help to alleviate the problem 1 Make sure that the chassis ground lug on the back of the power inverter is solidly connecte...

Page 5: ...o allow the heat to disperse The inverter s thermal protection prevents it from operating when its temperature exceeds 130 10 F 55 5 C SPE CIFICAT ION Name Des cription Input 12V 10 15V DC Output 115V AC Output frequency 60 Hz Output waveform Modified Sine Waveform Continuous power 1250 Watt Surge power 3000 Watt Efficiency Approx 90 No load current 0 3 A Battery low alarm 10 5 0 5 V DC Battery lo...

Page 6: ... of written instructions furnished Warranty Disclaimers This warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume any other liability in connection with the sale of our products There shall be no claims for defects or failure of performance or product failure under any theory of tort contract or commercial law including but not limited ...