Wagan LITHIUM CUBE EX18 User Manual Download Page 6

Lithium Cube™ EX18 by Wagan Tech

®

www.wagan.com

6

4. PRODUCT OPERATION

CHARGING THE CUBE
AC Charging

The intelligent fast-charging technology of Wagan supports an AC input power of 1000W. 

The smart charging system will preferentially harness solar power whenever the Lithium Cube is 

being recharged simultaneously by AC power and solar power.

e.g.

During simultaneous solar and AC charging, if the solar power is 300W, it will automatically 

adjust the AC charging to 700W. If the solar power rises to 600W during the midday sun, the 

Lithium Cube will drop the AC charging to 400W to make maximum use of solar power.

Please use the official Wagan cable for AC charging. Using the supplied AC Charging Cable, 

plug one end of the cable into the AC Charging input port on the back of the Lithium Cube, then 

plug the other end of the cable into an AC Wall outlet that supports a current of 10A or greater. 

Wagan is not responsible for any damage caused by using an unofficial charging cable or 

operating the product outside of specifications.

DC Charging

The DC charging cable is fused at 10 amps to prevent damage if there is an inadvertent short. 

Users can charge the product through the cigarette lighter port. Be sure to start the vehicle 

before using the DC Charging Cable to reduce the risk of depleting your vehicle’s battery.

To charge the Lithium Cube using the DC Charging Cable:

ONLY USE THE DC CHARGING CABLE SUPPLIED WITH THIS UNIT. 

1.  Note that the engine must be running while charging the Lithium Cube to avoid 

discharging the vehicle’s battery.

2.  Plug the DC charging cable into the Lithium Cube’s DC Anderson input port.
3.  Plug the other end of the DC charging cable into the vehicle’s accessory socket 

(cigarette lighter socket).

Solar Charging

The Lithium Cube’s DC input circuit is designed to maximize the charging profile based on the 

available power supplied, whether charging by the AC charger or solar panels via the Anderson 

port.

 

The Lithium Cube comes with a built-in 25A MPPT solar controller capable of charging up to 

600W. Do not use solar panels with their own built-in solar controller. Wagan is not responsible 

for any damage caused by using an unofficial charging cable. 

1.  To charge the Lithium Cube using a single solar panel, connect the solar panel using an 

Anderson connector compatible with the one built into the unit. The charge status will 

update on the display automatically.

Summary of Contents for LITHIUM CUBE EX18

Page 1: ...Item No 8837 User s Manual...

Page 2: ...e severely reduced or the product may cease to work WARNINGS identify important safety concerns when operating this equipment Failure to follow these warnings could result in personal injury or loss o...

Page 3: ...place it in an open area keep it away from combustible materials and people and dispose of it in accordance with local laws and regulations Do not move the product during use Movements may lead to poo...

Page 4: ...Anderson Input Port Anderson Output Port 12V DC Output DC Power Button UPS Overload Circuit Breaker AC Charging Input Port PARALLEL CONNECTION GROUND Main Power Button LCD Screen USB A Output Ports US...

Page 5: ...WHAT S INCLUDED Lithium Cube AC Charging Cable DC Charging Cable User s Manual LCD DISPLAY Battery Level Remaining Charge Discharge Time Input Power Output Power Battery Failure Warning High Temperat...

Page 6: ...age if there is an inadvertent short Users can charge the product through the cigarette lighter port Be sure to start the vehicle before using the DC Charging Cable to reduce the risk of depleting you...

Page 7: ...series If only two panels are connected you must connect the jumper cable to the third cable set in order for the panels to charge You can connect this cable to any cable set on the panel side of the...

Page 8: ...observe the power indicator 4 After appliance use turn OFF the AC power button 5 Remove AC appliance plug s from the AC outlets on the Lithium Cube 6 Recharge the Lithium Cube as soon as convenient No...

Page 9: ...approved by Wagan To prevent electric shock please do not plug any conductive objects into the parallel ports 2 Please make sure that the AC output is off before connecting the two units in parallel I...

Page 10: ...s data servers and workstations It is recommended that you test and confirm the compatibility of Lithium Cube with your devices before using the UPS function To avoid overload protection we recommend...

Page 11: ...harging ports the product supports most fast charging protocols Note When the USB output exceeds 5W the USB output wattage will be displayed on the screen Output voltage is reduced to 5V when both a f...

Page 12: ...can be extended if charging cable is connected to the Lithium Cube AC OPERATING TIME AC Powered Products Watts Estimated Run time 1 Clock Radio 10 115 hours WiFi Router 15 77 hours DVD Player 50 23 ho...

Page 13: ...an environment with a temperature between 68 F to 86 F away from water intense heat and other sharp objects If the remaining battery is less than 1 after you finish using the product please re charge...

Page 14: ...works properly High Temperature Charge Protection Let the unit cool down for 2hrs before recharge Battery Failure Contact Wagan Support Team No response after pressing the main power button System Hal...

Page 15: ...d device and restart the unit Do not use electrical devices that exceed the rated power of unit USB C Output Failure USB C Overload Protection USB C output will be resumed automati cally after you rem...

Page 16: ...anel s with a voltage of 11V 70V DC Solar Input Over Current Please use solar panel s within the input wattage of 600W 9 RECYCLING DISPOSAL If conditions permit make sure that the battery is fully dis...

Page 17: ...onnection Supports 2 Lithium Cube 8837 to parallel Protection Over Voltage Protection Overload Protection Over Temperature Protection Short Circuit Protection Low Tempera ture Protection Low Voltage P...

Page 18: ...ironmental Operating Temperature Optimal Operation Temperature 68 F 86 F Storage Temperature 4 F 113 F Charging Temperature 32 F 113 F DIscharging Temperature 4 F 113 F 11 OPTIONAL ACCESSORIES AA5476...

Page 19: ...s expressed or implied and no representative or person is authorized to assume any other liability in connection with the sale of our products There shall be no claims for defects or failure of perfor...

Page 20: ...gan com US CAN Toll Free 1 800 231 5806 Telephone 1 510 471 9221 31088 San Clemente Street Hayward CA 94544 U S A 2023 Wagan Corporation All Rights Reserved Wagan Tech and wagan com are trademarks of...

Reviews: