www.wagan.com

User’s Manual—Read before using this equipment

©2012 Wagan Corporation

All Rights Reserved.

Wagan Tech and 

wagan.com

 are trademarks used by Wagan Corporation.

14

6.  Connect the Negative (−) cable end to the inverter terminal and battery 

Negative Terminal. Make sure you have good, secure connections. 

7.  Recheck and make sure the DC cable fuse is installed in the fuse holder. 

CAUTION: Making an initial connection between the positive cable end 
and the inverter’s positive terminal may cause a spark. This is a normal  
and is a result of capacitors in the inverter starting to charge. Because 
of the possibility of sparking, it is extremely important that both the 
inverter and the battery bank be positioned away from any source of 
flammable fumes or gases. Failure to heed this warning can result in fire 
or explosion. Do not make the positive terminal connection immediately 
after the batteries have been charging. Allow time for the battery gasses 
to vent to outside air. 

8.  Attach the positive cable to the Positive (+) DC connector on the battery 

and then the inverter. Make sure the connections are tight and secure. 

9.  Turn ON the inverter from the Front Panel On/OFF Switch
10. Make certain that the green Operating LED is lit and the FAULT LED 

indicator is not lit.

11.  Turn OFF (0) the inverter. The Fault LED may briefly “flash”. This is 

normal. The audible alarm may also sound a short “chirp”. This is  
also normal. 

12. When you have confirmed that the appliance to be operated is turned 

off, plug the appliance into one of the two AC outlets on the front panel 
of the inverter. 

13. Turn the inverter on. 
14. Check operation of the Remote Switch – Press “Lock” to turn Off   

the inverter. 

15. Press the Unlock button to turn On the inverter.
16. Turn the appliance on. The appliance should begin working. 

17.  Observe the LED indicators and the Digital Display for Normal 

operation.

Note: If an extension cord is used from the inverter to the appliance, limit the 
extension cord length to 100 feet or less. Make sure that the cord is safety 
approved and AWG 14 or greater to carry the appliance load. Remember that 
extension cords are for temporary use.

Charging the Battery Bank 

It is not the purpose of this inverter user’s guide to provide detailed information 
regarding battery charging systems. However, the user should try to augment 
any stationary inverter charging system with either wind power or solar 
power. These can continue to operate during power outages and they also 
reduce recharge time. For mobile or marine charging systems, a higher rated 
alternator may be necessary to charge a battery bank.

Regular Loss of Commercial Power 

If the inverter system is used during commercial power outages that occur 
daily, configure the charger system to replace energy during the time that 
commercial power is available. 

Replacement of battery energy always requires more than was taken from 
the battery (typically 30 percent more). Follow battery manufacturer’s 
recommendations for maximum charging current.

Warning: 

T

here

 

is

 

danger

 

of

 

explosion

. do noT 

connecT

 

or

 

disconnecT

 

charger

 

cables

 

direcTly

 

afTer

 

baTTery

 

discharge

 

or

 

recharge

make

 

sure

 

ThaT

 

The

 

baTTery

 

bank

 

area

 

is

 

Well

 

venTed

 

before

 

aTTaching

 

or

 

removing

 

cables

If the flooded lead acid batteries are used, be sure that periodic checks of 
battery electrolyte levels are accomplished. Follow battery manufacturer’s 
instructions in keeping the electrolytes at the proper level. Be sure to use pure 
distilled water when replacing evaporated electrolyte liquid. 

Summary of Contents for Elite 5000W

Page 1: ...Item 2207 User s Manual Elite 5000W ...

Page 2: ...ns and refrigerators It also operates at high efficiency up to 90 that results in long running time and extended battery life compared to other inverters with this level of power output This inverter has the highest surge capability in its class Superior surge capability of 10 000 watts allows the inverter to start most difficult motorized appliances Advanced microprocessor controlled circuits run...

Page 3: ... of the inverter These terminals are for connecting 120 Volt AC devices that require more than 15 amps to operate or for connection to distribution wiring with multiple branches and AC outlets Any AC output wiring that is di rectly connected must comply with US National Electric Code NEC wir ing gauge recommendations Facing the Front Panel the terminals are Neutral and Ground are bonded connected ...

Page 4: ... feature To enable the Remote Switch the front panel On Off Switch must be in the On position To turn On the inverter momentarily press ON To turn the inverter Off momentarily press Lock If the wireless remote fails to control operation of the inverter you may be out of range for the radio signal move closer to the inverter If the Remote Switch has a depleted battery open the unit by unscrewing th...

Page 5: ...een battery bank and inverter Determining Maximum Appliance Wattage Microwave oven specifications list cooking power watts and appliance power Appliance power is the AC load the inverter has to supply Do not exceed the 5 000 watt maximum AC load or the inverter will shut down Most other electrical tools appliances and audio video equipment have labels that list the unit s power requirements in wat...

Page 6: ...a nominal 12 volt battery starts at 13 4 volts fully charged then drops to 10 5 volts discharged If the load on the battery causes the battery to discharge faster than the 20 hour rate the capacity AH of the battery is measurably reduced derated In heavy battery discharge applications double the estimated Amp Hour rating and configure batteries to support this capacity If the batteries are frequen...

Page 7: ...l result in a severe voltage drop that can cause damage to connectors conductors and insulation and can cause sparking Reverse polarity connection will blow the fuses in the inverter and can permanently damage to the inverter Damage caused by reverse polarity will void the warranty Installation Procedure 1 Mount the inverter in a secure location If the inverter is to be mounted on a wall mount it ...

Page 8: ...e Remote Switch Press Lock to turn Off the inverter 15 Press the Unlock button to turn On the inverter 16 Turn the appliance on The appliance should begin working 17 Observe the LED indicators and the Digital Display for Normal operation Note If an extension cord is used from the inverter to the appliance limit the extension cord length to 100 feet or less Make sure that the cord is safety approve...

Page 9: ...les from the 12 volt power source by running an extension cord from the inverter to the television set Troubleshooting PROBLEM Low or No Output Voltage Fault LED Lit Reason Solution Poor contact with battery or inverter terminals Clean terminals thoroughly Reinstall and tighten PROBLEM Inverter is Shut Down Fault LED Lit Reason Solution Battery voltage below 10 Volts Charge or replace battery Inve...

Page 10: ... Authorization number The item s must be returned with prepaid shipping WAGAN Corporation is not responsible for any shipping charges incurred in returning the item s back to the company for repair or replacement This warranty is void if the product has been damaged by accident in shipment unreasonable use misuse neglect improper service commercial use repairs by unauthorized personnel or other ca...

Page 11: ...rd CA 94544 U S A U S Canada Toll Free 1 800 231 5806 Tel 1 510 471 9221 customerservice wagan com www wagan com 2012 Wagan Corporation All Rights Reserved Wagan Tech and wagan com are trademarks used by Wagan Corporation REV20120612 ...

Reviews: