User’s Manual—Read before using this equipment

Load Considerations 

When an appliance with a motor starts, it requires a momentary surge of 
power. This surge of power is the “starting load” or “peak load”. Once 
started, the appliance requires less power to continue to operate. This is 
known as the “continuous load”. It is important to know the starting loads and 
the continuous loads of the appliances that are to be powered by the inverter. 

Appliance power is rated in watts. This information is usually stamped or 
printed on most appliances and equipment. In some cases, a tool will be rated 
in amperes. To convert from amps to watts, multiply: 

Amps x 120 (AC voltage) = Watts 

This formula yields an approximation of the continuous wattage load of that 
appliance. 

The startup load of an appliance is a major factor of whether this inverter can 
power it. 

Startup load is momentary. With many appliances, it is approximately twice 
the continuous load, but some appliance startup loads can be as high as eight 
times the continuous load. 

To determine if an appliance or tool will operate with this inverter, run a test. 
This inverter will automatically shut down in the event of an output overload, 
so there is no danger of damaging either the inverter or the equipment. When 
lit, a red LED indicator signals a fault.  

Planning the Inverter System 

Any large wattage inverter system requires planning before installation. There 
are several steps to the planning process so the user must determine the 
following: 

•  Maximum inverter wattage required. 
•  Operating time (run time) needed between battery recharges. 
•  Battery bank capacity in amp-hours. 
•  Charger requirement to charge batteries within a practical time. 
•  Distance between battery bank and inverter. 

Determining Maximum Appliance Wattage 

Microwave oven specifications list cooking power (watts) and appliance 
power. Appliance power is the AC load the inverter has to supply. Do not 
exceed the 3,000 watt maximum AC load or the inverter will shut down.

Most other electrical tools, appliances, and audio/video equipment have 
labels that list the unit’s power requirements in watts. If the tool or device is 
rated in amps, multiply the amps by 120 (120V AC) to determine the watts. For 
example, a power tool rated at 4 amps will draw 480 watts. 

Remember to consider the startup surge that motorized appliances will cause. 
Do not exceed the 6,000 watt surge rating of this inverter this can cause 
immediate overload shut down. 

At 3,000 watts continuous output, this inverter requires a DC power supply 
(battery bank) that can continuously supply 200 amps at 12V DC for the 
duration of the run time. 

Configuring the Battery Bank 

To determine the minimum battery ampere-hour rating that you will need to 
operate appliances from the inverter and any DC appliances powered by the 
battery bank, follow these steps: 

1.  List the maximum continuous wattage that the inverter has to supply. 
2.  Estimate the number of hours the appliances will be in use between 

battery recharges. This will vary depending on appliances. For example, 
a typical home-use coffee maker draws 500 watts during its brew 
time of 5 minutes. It maintains the temperature of the pot, requiring 
100 watts. Typical use of a microwave oven is only for a few minutes. 
Some longer operating time appliances are lamps, TVs, computers and 
refrigerator/freezers.

Determine the total watt-hours of energy needed. This is done by multiplying 
average power consumption in watts by hours of run time. For example: 500 
watts for 10 hours = 5000  watt hours. To get an estimate of the maximum 
current (in amps) that a battery bank must be capable of delivering to the 
inverter, divide the load watts by ten. For example a 500 watt appliance load 
will need 50 amps at 12 volts DC. Using the 500 watts (or 50 amps) for 10 

Summary of Contents for Elite 3000W

Page 1: ...Item 2206 User s Manual SHEMO080100244TXC ...

Page 2: ...h this level of power output This inverter has the highest surge capability in its class Superior surge capability of 6 000 watts allows the inverter to start most difficult motorized appliances Advanced microprocessor controlled circuits run cooler and are more reliable than competing units General Instructions Keep the inverter away from any direct heat source or combustible materials Keep well ...

Page 3: ...with multiple branches and AC outlets Any AC output wiring that is directly connected must comply with US National Electric Code NEC wiring gauge recommendations Facing the Front Panel the terminals are Neutral and Ground are bonded connected inside the inverter to comply with the NEC requirement that any AC source must have a Neutral to Ground connection Ground Terminal The Ground Terminal is loc...

Page 4: ... feature To enable the Remote Switch the front panel On Off Switch must be in the On position To turn On the inverter momentarily press ON To turn the inverter Off momentarily press Lock If the wireless remote fails to control operation of the inverter you may be out of range for the radio signal move closer to the inverter If the Remote Switch has a depleted battery open the unit by unscrewing th...

Page 5: ...ween battery bank and inverter Determining Maximum Appliance Wattage Microwave oven specifications list cooking power watts and appliance power Appliance power is the AC load the inverter has to supply Do not exceed the 3 000 watt maximum AC load or the inverter will shut down Most other electrical tools appliances and audio video equipment have labels that list the unit s power requirements in wa...

Page 6: ...nal 12 volt battery starts at 13 4 volts fully charged then drops to 10 5 volts discharged If the load on the battery causes the battery to discharge faster than the 20 hour rate the capacity AH of the battery is measurably reduced derated In heavy battery discharge applications double the estimated Amp Hour rating and configure batteries to support this capacity If the batteries are frequently ch...

Page 7: ...ch located on the front panel of the inverter is in the OFF 0 position 5 Locate the ground lug terminal on the inverter Connect an insulated 10 gauge copper wire to the terminal The other end of the ground wire is connected to a proper grounding point Use the shortest practical length of wire Connect this wire to the chassis of your vehicle or to the grounding system in your boat In a city the gro...

Page 8: ...may be necessary to charge a battery bank Regular Loss of Commercial Power If the inverter system is used during commercial power outages that occur daily configure the charger system to replace energy during the time that commercial power is available Replacement of battery energy always requires more than was taken from the battery typically 30 percent more Follow battery manufacturer s recommen...

Page 9: ...uous power output Unit may be defective See warranty and call customer service PROBLEM Inverter Shut Down Fault LED Lit OVL Display Reason Solution Equipment being operated draws too much power Use a higher capacity inverter or do not use this equipment PROBLEM Continuous Buzzing Sound Display Shows Low Voltage Reason Solution Input voltage below 10 5 Volts Keep input voltage above 10 5 Volts Poor...

Page 10: ... original store receipt The replacement product will be in warranty for the balance of the original two 2 Year warranty period To return a defective item please contact WAGAN Corporation at 800 231 5806 to obtain a Returned Merchandise Authorization number RMA and return instructions Each item returned will require a separate RMA After you have received the RMA and the return instructions from WAG...

Page 11: ...rd CA 94544 U S A U S Canada Toll Free 1 800 231 5806 Tel 1 510 471 9221 customerservice wagan com www wagan com 2012 Wagan Corporation All Rights Reserved Wagan Tech and wagan com are trademarks used by Wagan Corporation REV20120613 ...

Reviews: