background image

WAECO USA

• Page 4

CHANGING THE FACE PANEL

After loosening the screws (1 and 3), the parts (2 and 4) can
be dismounted. Now the door panel can be pulled out. 

CHANGING THE DOOR HINGE POSITION

Dismount the top hinge (1) and pull out the door. Unscrew
the locking hook (3) and pull out the locking bar. Dismount
the stopper (4) and place it on the opposite side. Complete
the locking system. Now exchange the position of the 
fastener, (5) and hinges (1) and add the door.

TRANSPORT LOCKING SYSTEM

1. Door is closed and secured.

2. Securing device inactive; door can be opened.

3. Door secured in vent position; door is slightly opened.

INSTALLATION INSTRUCTIONS 
FOR 12/24 VOLT REFRIGERATORS

In order to ensure adequate ventilation, air channels must be
provided over the entire width of the refrigerator as shown
in the sketch below. 

ATTENTION: 

Air circulation must never be restricted or even

interrupted.

min. 1.9”

w

ar

m

 o

ut

go

in

ai

r

w

ar

m

 o

ut

go

in

ai

r

co

ld

 in

co

m

in

ai

r

co

nd

en

se

r

m

in

. 1

.1

w

it

fa

ce

 p

an

el

 1

.9

Summary of Contents for RPD Series

Page 1: ...to change without notice Tel 860 664 4911 Fax 860 664 4912 www waecousa com WAECO USA Inc 1 WAECO USA Clinton CT www waecousa com Installation Operating Manual FRONT LOADING COMPRESSOR REFRIGERATORS...

Page 2: ...ate medicines first check if the refrigerator s cooling capacity meets the demands of the respective remedies The refrigerator is designed to operate in ambient temperatures between 14 F and 130 F in...

Page 3: ...ATTENTION The refrigerator may need up to 60 seconds for the compressor to start TAKING OUT OF SERVICE If you wish to switch off the refrigerator for longer periods of time disconnect the AC supply o...

Page 4: ...the position of the fastener 5 and hinges 1 and add the door TRANSPORT LOCKING SYSTEM 1 Door is closed and secured 2 Securing device inactive door can be opened 3 Door secured in vent position door is...

Page 5: ...WAECO USA Page 5 CONNECTION DIAGRAM...

Page 6: ...WAECO USA Page 6 REMOTE MOUNTING THE COOLING UNIT For RPD RSD RSF APPLIANCES The detachable cooling unit can be installed separately...

Page 7: ...with electronics Electronics defective Replace electronics Interruption in compressor s electronic system between the pins Compressor defective Replace compressor Interior temperature too low at ther...

Page 8: ...m an authorized service agent for one year from date of purchase or third party installation For OEM factory installed prod ucts the duration is one year from the date of purchase of the vehicle vesse...

Reviews: