Waeco RAPS 36 Operating Instructions Manual Download Page 4

Instructions CoolPower 

36

4

4. Testing

Disconnect the charge lead and press the button on your CoolPower
front panel 

whilst your fridge is running

.

4.1  Voltage

Your battery voltage will appear on the digital display. The precise
remaining capacity will vary depending on conditions such as ambient
temperature, but as a general guide will be as follows:

Voltage

Capacity

12.8V or more

80%  - 100%

12.3V to 12.7V

40%  -   80%

11.3V to 12.2V

20%  -   40%

4.2  LED’s (on front panel)

A quick visual indication of the condition of your CoolPower can be
obtained at a glance. After disconnecting charging leads and pressing
the test button:

LED Condition

(Voltage)

Action Required

‘FULL’ (green)  

ON

(12.8V or more)

None

Both  

OFF

(11.4V to 12.7V)

Charging optional

‘LOW’ (red)  

ON

(11.3V or less)

Must Charge

5.  Charging

5.1  In-car (12V)

-

Plug the charge lead 2-pin screw connector into the ‘CHARGE’ 
socket on the left hand side of your CoolPower. Then plug the 
cigarette plug on the other end of the charge lead either directly 
into your vehicle cigarette socket, or (recommended) into the
WAECO  RAPS12R-U fast charge kit socket pre-fitted to your
vehicle.

-  When the CoolPower is accepting charge from your vehicle battery,

the green LED adjacent to the ‘CHARGE’ socket will illuminate.

5.2   240V mains

-

The specified maximum charging current is 12A, however a 6A or
8A charger (WAECO models MBC600 and MBC800) is recommended
as adequate for your CoolPower36.

-

An automatic cutout charger must be used, otherwise
irreparable damage will occur and your warranty voided

.

-

Disconnect your fridge and DC charging lead from the battery.

CoolPower36_41102  30/10/04  11:55 AM  Page 5