CoolPower EPS100
Technical description
17
5
Technical description
The mains rectifier can operate all coolers and refrigerators with BD35F com-
pressors at 230 V. With a 230 V mains connection, the rectifier automatically
switches from battery to mains operation.
When disconnected from the 230 V mains supply, the rectifier automatically
switches back to battery operation. Mains operation via the rectifier always
takes priority over battery operation.
5.1
Control elements
6
Mounting the mains rectifier
If you wish to mount the mains rectifier in a fixed position, please observe the
following
mounting instructions
:
z
Do
not
mount the device
– In wet or damp environments
– In the vicinity of combustible materials
– In areas where there is a danger of explosions
z
The place of installation must be well-ventilated. A ventilation system
which is at least equivalent to the air openings in the device must be
present for installations in closed housings.
Item in
fig.
1
, page 3
Explanation
1
Mains cable
2
Fastening bracket
3
Self-tapping screws
4
12 V socket
5
Glass fuse (250 V, 4 A, slow-blow)
6
Compressor output terminals
7
Battery input terminals