CD-32-AC
Cleaning and maintenance
25
6.6
Switching off the cooler
➤
Empty the cooler.
➤
Switch the cooler off.
➤
Pull out the connection cable.
If you do not want to use the cooler for a longer period of time:
➤
Leave the lid slightly open. This prevents odour build-up.
6.7
Replacing the plug fuse (12 V)
➤
Pull the adapter sleeve (fig.
6
4, page 3) off of the plug.
➤
Unscrew the screw (fig.
6
5, page 3) out of the upper half of
the housing (fig.
6
1, page 3).
➤
Carefully lift the upper half of the housing off from the lower
(fig.
6
6, page 3) half.
➤
Take out the contact pin (fig.
6
3, page 3).
➤
Replace the defective fuse (fig.
6
2, page 3) with a new fuse
that has the same rating.
➤
Re-assemble the plug in the reverse order.
7
Cleaning and maintenance
Caution - Danger of electrocution!
Always disconnect the mains plug before you clean and service the
device.
Caution - Danger of damaging the device!
Never clean the device under running water or in dish water.
Do not use abrasive cleaning agents or hard objects during clean-
ing as these can damage the device.
➤
Clean the inside of the device with a damp cloth now and again.
CD-32-AC.book Seite 25 Donnerstag, 17. November 2005 3:23 15