CoolFreeze

Technical Data

CF-18

Slide the sliding switch (Fig.  

4, page 4) to “LOW” or “HIGH” 

battery protection (See 6.4 “using the battery monitor” for suitable 
level).

The “POWER” LED is lit green.

The cooler starts cooling the interior.

When the cooling temperature has been reached, the “POWER” LED
is lit amber.

CF-25, CF-35, CF-40, CF-50, CF-60

Press the “ON/OFF” button (Fig.  

1, page 5) and hold down for 

between one and two seconds.

The “POWER” LED lights up.

The display (Fig.  

4

5, page 5) switches on and shows the current 

temperature.

Note – Displayed temperatures (Digital display models only)

.

CF-25, CF-35, CF-40, CF-50, CF-60 (Not CF-50DZ)

The temperature displayed is that of the middle of the large interior 
compartment.

CF-50DZ

With plastic dividers in

: the display temperature is that of the 

middle of the freezer compartment (furthest away from control 
panel).

ii 

With plastic dividers removed

: the actual compartment 

temperature  will be considerably warmer than the displayed 
temperature.

ALL MODELS

Temperatures elsewhere in the compartment (away from centre) will
deviate from the displayed temperature.

The cooler starts cooling the interior.

Locking the cooler

Close the lid.

Press the lock (Fig.  

2

1, page 4) down, until it latches in place 

audibly.

CF18-60_M_81003:PowerVac_PV-100  3/9/08  3:53 PM  Page 19

Summary of Contents for CF-1

Page 1: ...M_81003 CF 18 CF 25 CF 35 CF 40 CF 50 CF 50DZ CF 60 AUS Compressor Cooler Instruction Manual CF 40 AC CF 50 AC CF 50 ACDZ CF 60 AC CF 25 CF 18 CF 35 AC...

Page 2: ...nded use 10 5 Function description 11 5 1 Operating and display elements 12 5 2 Accessories 14 6 Operation 14 6 1 Before initial use 14 6 2 Energy saving tips 15 6 3 Connecting the cooler 16 6 4 Using...

Page 3: ...4 CoolFreeze 1 4 2 3 1 12 24V DC COLD FREEZE ERROR POWER HIGH 0 LOW TEMPERATURE BATTERY MONITOR 1 2 3 4 5 1 2 3 CF 25 CF 35 CF 40 CF 18...

Page 4: ...FF SET POWER UP DOWN ERROR 1 3 4 5 6 7 2 1 2 1 4 7 12 24V DC 1 4 5 CF 25 CF 35 CF 40 CF 50 CF 60 CF 35 CF 40 CF 50 CF 60 CF 25 CF 35 CF 40 CF 50 CF 60 100 240V AC FUSE EMERGENCY OVERRIDE NORMAL USE 1...

Page 5: ...6 CoolFreeze 8 1 2 3 4 5 6 9 1 2 10 CF 50 CF 60 A B...

Page 6: ...device Action This symbol indicates that action is required on your part The required action is described step by step This symbol indicates the result of an action Fig 2 1 page 3 This refers to an el...

Page 7: ...plug out of the cigarette lighter or the socket by the cable Pull out the connection cable Before cleaning and maintenance After use Before changing a fuse Disconnect the cooling device and other powe...

Page 8: ...protected against splashing water Protect the device and the cable against rain and moisture Do not place the device near naked ames or other heat sources heaters direct sunlight gas ovens etc Caution...

Page 9: ...CF 25 CF 50DZ 2 CF 50DZ only Powdercoated steel basket 2 CF 50DZ only Internal compartment divider plastic 1 Operating manual 4 Intended use The cooler is suitable for cooling and freezing foods The...

Page 10: ...ed grips CF 25 or two removable carrying handles CF 35 CF 40 CF 50 CF 60 When used on boats the cooler can withstand a constant heel inclination of 30 Scope of functions CF 18 CF 25 CF 35 CF 40 CF 50...

Page 11: ...10 C 50 F FREEZE 18 C 0 F 2 POWER Operating display LED is lit green Device is switched on and ready for operation LED is lit amber Set temperature has been reached 3 ERROR LED ashes red Switched on...

Page 12: ...cient 3 ERROR LED ashes red Device is switched on but not ready for operation 4 SET Selects the input mode Temperature setting Celsius or Fahrenheit display Set battery monitor 5 Display shows the inf...

Page 13: ...Cleaning and maintenance on page 22 Mounting the handles CF 35 CF 40 CF 50 CF 60 The handles are enclosed unassembled If you wish to attach the handles proceed as follows Make a handle by putting two...

Page 14: ...Fahrenheit The selected temperature units then appear in the display for a few seconds The display ashes several times before it returns to the current temperature 6 2 Energy saving tips Choose a wel...

Page 15: ...r handle plugs and switches with wet hands or if you are standing on a wet surface Caution Danger of electrocution If you are operating your cooler on board a boat from a mains connection of 100 240 V...

Page 16: ...the digital display Fig 4 5 page 5 goes blank and the power LED Fig 4 2 page 5 ashes amber Caution Danger of damage When switched off by the battery monitor the battery will no longer be fully charged...

Page 17: ...from the AC mains set the battery monitor to the LOW position 6 5 Using the cooler Caution Danger of overheating Ensure at all times that there is suf cient ventilation so that the heat generated duri...

Page 18: ...ture Note Displayed temperatures Digital display models only CF 25 CF 35 CF 40 CF 50 CF 60 Not CF 50DZ The temperature displayed is that of the middle of the large interior compartment CF 50DZ i With...

Page 19: ...ORMAL USE position In the unlikely event of an electronic control failure slide the Switch to EMERGENCY OVERRIDE NOTE in this position the appliance will run all the time and will therefore perform as...

Page 20: ...he fuse insert Fig 6 2 page 5 with a screwdriver Replace the defective fuse with a new one that has the same rating T4 0AL 250V Press the fuse insert back into the housing 6 11 Replacing the plug fuse...

Page 21: ...ger of electrocution Always pull out the mains plug before you clean and service the device Caution Danger of damaging the device Never clean the device under running water or in dish water Do not use...

Page 22: ...socket is dirty This results in a poor electrical contact The fuse of the 12 24 V plug has blown The vehicle fuse has blown The device has switched off due to an internal fault Suggested remedy The ig...

Page 23: ...A 7 0 A 7 0 A 24 VDC 3 0 A 3 0 A 3 0 A 100 240 VAC 1 3 to 0 7 A 1 3 to 0 7 A 1 3 to 0 7 A Cooling range 10 C to 18 C 50 F to 0 F Dimensions WxHxD in mm Weight 17 kg CF 50 19 kg 21 5 kg CF 50DZ 19 8 kg...

Page 24: ...i cates 73 23 EEC Low Voltage Electrical Equipment Directive 89 336 EEC EMC Directive 95 54 EEC Versions and delivery options may vary due to technical modi cations This device is CFC free The coolant...

Page 25: ...26 CoolFreeze...

Page 26: ...27 CoolFreeze...

Page 27: ...O phone 39 051 727094 fax 39 051 727687 e mail sales waeco it WAECO Norge AS Leif Weldingsvei 16 N 3208 Sandefjord phone 47 33428450 fax 47 33428459 e mail rmapost waeco no WAECO Benelux B V Ecustraat...

Reviews: