EN
Multi Gas
Operating the leak detector
7
6.1
Control elements
7
Operating the leak detector
7.1
Before initial use
I
7.2
Switching on the leak detector
➤
Press the start button (fig.
4, page 2) to switch on the device.
✔
The device regenerates the sensor for 35 seconds.
✔
The LED bar graph lights up several times from left to right.
✔
It emits one beep. The device is ready to use.
No. in
fig.
Description
Explanation
1
Loudspeaker
Beep is emitted when a leak is detected.
2
LED bar graph
This shows the size of the leak and ensures
the precise location of the leak can be found
quickly. The nearer or larger the leak is, the
more bars are shown.
3
Green LED
LED lights up: batteries are charged
LED does not light up: batteries are charged
10 %
4
START button
switches the device on and off
switches between the four sensitivity levels
5
Sensor tip
–
6
Metal probe
–
7
3 white LEDs
(L, M, S)
indicate leaks with R1234yf
8
3 blue LEDs
(L, M, S)
indicate leaks with R134a and all other gases
NOTE
Insert the batteries (fig.
3, page 2) before you use the device
for the first time.