Decommissioning
11.1 Temporary decommissioning
40
Operator’s manual | VP | 5100056064 | 02/2020 | [en]
11
Decommissioning
11.1
Temporary decommissioning
Information
Further information and detailed descriptions,
.
If the machine is stationary for more than 1 month, perform the following
measures:
Entire machine.
• Clean thoroughly.
• Check for leaks, rectify any defects if necessary.
• Store dust-free and dry.
Fuel tank.
Plastic tank
:
• Drain fuel completely.
Metal tank:
• Refill with fuel.
Engine.
• Check engine oil level, top up engine oil, if necessary.
• Check and clean air filter.
• Clean fuel filter.
Corrosion-prone components such as safety
bolt, spindle and throttle cable.
Oil and grease.
If the machine is shut down for more than 6 months, contact a service
partner.
11.2
Final shutdown
If the machine is no longer in use and is shut down for good, all operating
fluids must be drained.
Have the machine professionally dismantled and disposed of by a state-
approved recycling company.
Professional disposal of this machine avoids negative effects on human
health and the environment, helps with the targeted treatment of pollut-
ants and makes it possible to recycle valuable raw materials.