
ghi_tx001462gb_FM10.fm
56
Operation
HI400HD D / HD G
4.28
Installing and Using the Remote Thermostat
Requirements
■
Remote thermostat
■
Pre-starting checks complete
Procedure
Perform the procedure below to install and use the remote thermostat.
1. Remove the thermostat receptacle plug
(a)
from the control panel receptacle.
2. Connect the remote thermostat
(b)
to the control panel receptacle
(c)
.
3. Set the sensor end
(d)
within the area to be heated.
4. Adjust the target temperature with the dial
(e)
.
Thermostat
adapter
An adapter is available to convert the proprietary thermostat connection to an
Edison plug-style connection for use with commonly available thermostats. This
adapter can be purchased using Wacker Neuson part #5200007098.
NOTICE:
The thermostat adapter is designed for use ONLY with a thermostat. To
avoid damaging the machine, do not plug any other equipment into the thermostat
adapter.
wcghi_gr007373
c
b
a
b
e
d
Summary of Contents for HI400HD D
Page 4: ...CALIFORNIA Proposition 65 Warning Proposition 65 Warning 4 wc_tx004643en fm Notes ...
Page 8: ...Foreword HI400HD D HD G 8 ghi_tx001460gb_FM10 fm ...
Page 12: ...12 wc_bo5000192824_11TOC fm HI400HD D HD G Table of Contents ...
Page 27: ...ghi_si000469gb_FM10 fm 27 HI400HD D HD G Labels Fork lift pocket ...
Page 85: ...wc_td000604gb_FM10 fm 85 HI400HD D HD G Technical Data Notes ...
Page 92: ......
Page 94: ......