Installation
Place the generator in an area where it will not be exposed to rain,
snow, or direct sunlight. Make sure it is positioned on firm, level
ground, so it will not slide or shift. Position the engine exhaust away
from areas where people may be present.
T
he surrounding area must be free from water and moisture. All
components must be protected from excessive moisture.
Using a generator indoors CAN KILL YOU IN MINUTES. Generator
exhaust contains carbon monoxide. This is a poison you cannot see or
smell. NEVER use this generator inside a home or garage, EVEN IF
doors and windows are open. Only use this generator OUTSIDE and
far away from windows, doors, and vents.
NEVER install a generator in an enclosed area such as a tunnel or a
trench. Using a generator in a tunnel or a trench CAN KILL YOU IN
MINUTES. Generator exhaust contains carbon monoxide. This is a
poison you cannot see or smell. NEVER use this generator inside a
tunnel or a trench.
3.3
Installing Spark Arrester
A spark arrester is available as an accessory for this machine. Install
the spark arrester prior to using the machine in areas where spark
arresters are required.
To install spark arrester:
3.3.1
Position the spark arrester
(a)
on the engine exhaust pipe
(b)
.
3.3.2
Secure the spark arrester with screw
(c)
included with spark arrester.