GP 3800A
16
wc_si000555gb.fm
C
—
DANGER!
Read the Operator’s Manual.
No sparks, flames, or burning objects near
the machine.
Stop the engine before refueling.
—
GFCI TEST INSTRUCTIONS - TEST BEFORE EACH USE
Normal operating state - sensing device green LED is "ON" and circuit breaker is at "ON" position.
Step 1:
Press "TEST" button. Green LED should go "OUT" and red LED should come "ON" and
circuit breaker should trigger to "OFF" position.
Step 2:
If sensing device LED or breaker does not trip or change state, "DO NOT USE". Consult
an electrician for assistance.
Step 3:
Press "RESET" button. Red LED should turn "OFF" and green LED should turn "ON".
Step 4:
Manually reset (switch) circuit breaker to "ON" position to restore circuit power.
D
—
—
CAUTION!
Use only clean, filtered gasoline fuel.
Check the fuel level.
—
Open the fuel flow valve.
—
Close the choke.