Operation
GP 2500A
wc_tx000447gb.fm
18
5.2
Outdoor Installation
Place the generator in an area where it will not be exposed to rain,
snow, or direct sunlight. Make sure it is positioned on firm, level
ground, so it will not slide or shift. Position the engine exhaust away
from areas where people may be present.
If operating the generator inside a tunnel or deep trench, make sure
there is adequate ventilation. Precautions similar to those required
when operating indoors may be necessary.
The surrounding area must be free from water and moisture. All
components must be protected from excessive moisture.
5.3
Indoor Installation
If the generator must be installed indoors, adequate ventilation or
exhaust hoses must be provided. When venting exhaust fumes, make
sure the exhaust piping is large enough to prevent excessive back
pressure to the engine. Back pressure reduces engine efficiency and
may cause the engine to overheat.
Exhaust gas from the engine contains poisonous carbon monoxide
gas; exposure to carbon monoxide can cause loss of consciousness
and may lead to death. Never run the generator indoors or in an
enclosed area unless adequate ventilation, through such items as
exhaust hoses or fans, is provided.
When installed indoors, steps to prevent fire and explosion such as
providing a good, earthen ground, removing all flammable materials
near the generator, and using only electrical cables in good condition,
must be observed. See
Operating Safety.
DANGER
Summary of Contents for GP 2500A
Page 1: ...www wackergroup com Generator GP 2500A OPERATOR S MANUAL 0160531en 002 1106 0 1 6 0 5 3 1 E N...
Page 13: ...GP 2500A Safety Information wc_si000149gb fm 11 3 5 Label Locations GND 88897...
Page 37: ...GP 2500A Maintenance wc_tx000448gb fm 35...
Page 38: ...Maintenance GP 2500A wc_tx000448gb fm 36 Notes...
Page 39: ......