Initial Setup and Overview
G 14
38
wc_tx001185gb.fm
3.13
Voltage Output
Description
The G 14 is capable of providing output voltages of 120V or 240V depending upon
how the power cables are attached to the customer connection lugs.
Using output
voltages
Connecting power cables to L1 and N, or L2 and N, will produce 120V output
voltage.
Connecting power cables to L1 and L2 will produce 240V output voltage.
Two pieces of equipment requiring 120V can be operated at the same time
provided one is connected to L1 and N, and the other is connected to L2 and N.
3.14
Ground Connection
Location
The ground connection
(w)
is located next to the connection lugs.
Connection
Connect the ground lug to a good earthen ground for proper operating safety in
compliance with NEC and local standards.
L1
N
L2
120V
120V
240V
wc_gr006202
WARNING
Electrocution hazard! High voltage is present inside the hinged terminal door when
the generator is operating.
f
Do not open the hinged terminal door unless the engine is stopped.
wc_gr006208