Safety
Specific safety instructions when operating electrical appli-
ances 4.8
15
[en] | 09/2020 | 5100056242 | FUH | Operator’s manual
4.7.3
Handling and use
• Handle machines with care. Do not operate machines whose com-
ponents or control elements are defective. Have defective compon-
ents or control elements replaced immediately. Machines with defect-
ive components or control elements entail a high risk of injury!
• Do not lock, manipulate or alter the machine operating elements in an
inadmissible manner.
• Secure unused machines against unauthorized commissioning. The
machine may only be operated by authorized personnel.
• Handle machine with care. Have defective parts replaced immedi-
ately before this machine is commissioned. Defective machines entail
a high risk of injury.
• Use the machine, accessories, tools etc. in accordance with these in-
structions.
• After operation, store the machine in a locked, clean, frost-protected,
and dry location that is inaccessible to other persons and children.
4.8
Specific safety instructions when operating electrical appliances
Information
The rated voltage can be found on the type label of the machine.
Power supply for electrical devices of protection class I
Connect the machine to a plug receptacle with 15 A/16 A earth contact
and appropriate safety fuse.
One of the following earth-leakage circuit breakers is required:
• Standard earth-leakage circuit breaker (pulse current sensitive, type
A).
• All-current sensitive earth-leakage circuit breaker (type B).
Only connect the machine to power supplies if all machine parts are in
perfect technical condition. Pay particular attention to the following com-
ponents:
• Plugs.
• Power cable over the entire length.
• Switch membrane of the on/off switch, if present.
• Plug receptacles.
Only connect the machine to power supplies with an intact grounding
conductor connection (PE).
When connected to stationary or mobile generators, at least one of the
following safety devices must be provided:
• Earth-leakage circuit breaker.
• ISO guard.
• IT network.
Only connect the machine to an grounded site power distributor.