13 Technical data
EH 6, EHB 7
58
Extension cable for the US market:
Example
You utilize an EHB 7 M/230 and want to use an extension cable with a length of
50 m (164 ft).
The machine has an input voltage of 230 V.
According to the table, the extension cable must feature a cross-section area of
1.5 mm
2
(AWG 16).
110-120 1~
< 22
1.5
< 37
2.5
< 59
4.0
Voltage
[V]
Extension
[ft]
Cross-section
area of cable
[AWG]
220-240 1~
< 246
16
< 390
14
110-120 1~
< 102
14
< 161
12
< 253
10
Voltage
[V]
Extension
[m]
Cross-section
area of cable
[mm
2
]
Summary of Contents for EHB 7
Page 1: ...www wackerneuson com Operator s manual Electric hammer EH 6 EHB 7 04 2010 0217536en 004...
Page 5: ...EH 6 EHB 7 5...
Page 12: ......
Page 61: ......
Page 62: ......