Maintenance
EHB 11
40
Operator’s manual
Lubricating the crank mechanism
Only use special lubricants for lubricating.
For further information, refer to chapter
Technical Data
.
1. Place filled grease gun onto the zerk fitting and operate 5 to 6 times.
2. Wipe off zerk fitting with a clean cloth.
Checking the tool holder for wear
f
Measure the tool play 200 mm from insertion point.
Play may not exceed 6 mm.
If the play exceeds 6 mm, the tool holder bushing in the tool holder must be re-
placed.
Item
Designation
1
Zerk fitting
Item
Value
A
200 mm
B
Max. 6 mm