background image

SV00011GB

3

SAFETY INSTRUCTIONS

SAFETY INSTRUCTIONS FOR THE USE OF DRILLING AND

BREAKING HAMMERS WITH ELECTRIC DRIVE

General instructions

1.

Drilling and breaking hammers may only be operated by persons who

*

are at least 18 years of age,

*

are physically and mentally fit for this job

*

have been instructed in operating drilling and breaking hammers and proven their ability for the job
to the employer

*

may be expected to carry out the job they are charged with carefully.

The persons must be assigned the job of operating drilling and breaking hammers by the employer.

2.

Drilling and breaking hammers are to be applied for their proper use. Both the manufacturer’s operator’s
manual and these safety instructions have to be observed.

3.

The persons charged with the operation of these hammers have to be made familiar with the necessary
safety measures relating to the machine. In case of extraordinary uses, the employer shall give the
necessary additional instructions.

4.

It is possible that these drilling and breaking hammers exceed the admissible sound level of 89 dB (A).
Operators must wear personal hearing protection if the admissible assessment sound level equals or
exceeds 89 dB (A).

Operation

1.

The function of operation levers or elements is not to be influenced or rendered ineffective.

2.

Make sure that the machine is connected only to voltage and frequency as indicated on its name plate.
Choose correct cross section for extension cord. See method of calculation instructions with diagram in
this manual.

3.

The operator has to switch off drilling and breaking hammers, to disconnect them from the electric mains
and to store them in such a manner that they do not turn over be fore leaving the machines or going on
breaks.

4.

Wear safety goggles in order to avoid injuries to the eyes.

5.

We recommend wearing suitable working gloves.

6.

Wear safety shoes while working with drilling and breaking hammers.

7.

Drilling and breaking hammers are always to be operated with both hands on the handles provided for
this purpose.

8.

When working with drilling and breaking hammers, especially when carrying out drilling jobs, the opera-
tor has to have a firm stand, particularly when working on scaffolding and ladders.

9.

Drilling and breaking hammers are to be guided such that hand injuries caused by solid objects are
avoided. When carrying out demolition jobs at elevated places, special care is required to prevent the
machine or the operator from falling.

10.

Avoid body contact with earthed components. When breaking connecting passages, make sure that
there are no electric wires or gas pipes. No one may stay in the room to which the passage is broken
through, as there is danger of injuries because of falling stones or tools.

11.

During operation the tool holder must be closed. Tools and tool holder must be checked for wear in order
to guarantee proper functioning of holder.

12.

The operation of this machine may cause broken - off pieces to be flung away. Therefore, during oper-
ation, no one except the operator is to come near this machine.

13.

Drilling and breaking hammers have to be disconnected from the electric mains before changing tools.

14.

The tools always have to be in perfect conditions.

15.

Do not operate these machine in areas where explosions may occur.

Summary of Contents for EHB 10 series

Page 1: ...www wackergroup com Operator s Manual Electrik hammer EHB 10 0200071en 001 11 2005...

Page 2: ......

Page 3: ...reserved Copyright by Wacker Construction Equipment AG No part of this publication may be reproduced in any form or by any means electronic or mechanical including photocopying without express permis...

Page 4: ...port 4 Maintenance checks 4 TECHNICAL DATA 5 DESCRIPTION 6 Application 6 Putting into operation 6 During operation 6 Disassembly 7 Assembly 7 MAINTENANCE 8 Maintenance schedule 8 Maintenance and lubri...

Page 5: ...to switch off drilling and breaking hammers to disconnect them from the electric mains and to store them in such a manner that they do not turn over be fore leaving the machines or going on breaks 4...

Page 6: ...use original spare parts Modifications to this machine including the adjustment of the maximum engine speed set by the manufacturer are subject to the express approval of Wacker In case of non observa...

Page 7: ...00 Drill speed electronic control min 1 170 265 Special lubricating grase Grease Unirex N2 Shaft for drilling tools hexagonal SW 19 x 80 Shaft for breaking tools SW 19 x 82 5 Power transmission percus...

Page 8: ...sulting in seizure 2 Connectionn This electric hammer is powered by 230 240 V A C single phase A suitable plug is provided for connec tion During operation 1 Changing the application The position for...

Page 9: ...tapping screws remove cover Take both carbon brushes out of brush holder Access to stator pack and rotor Remove cheese head screws remove bearing bracket from crankcase Remove self tapping screws the...

Page 10: ...ght fit retighten if necessary 25 Nm Miscellaneous Regrease crankshaft drive 600 hours Maintenance and lubrication 1 General instructions Keep hammer and tools clean 2 Motor Carbon brushes This hammer...

Page 11: ...mm Effective length 190 mm 0109320 Star profile chisel Effective length 250 mm 0109321 Blank Effective length 660 mm 0034103 Flat spade wide 90 mm Effective length 280 mm 0022769 Asphalt spade wide 8...

Page 12: ...Carbide tipped twist drill We recommend predrilling with short drill 400 mm WI 22 mm 25 mm 28 mm 32 mm 40 mm 45 mm 0096634 0096635 0096636 0096637 0096638 0096639 550 mm WI 35 mm 55 mm 65 mm 80 mm 009...

Page 13: ...290 0124291 0124292 0124293 0124294 0124295 Cross drill crown type X 35 mm 40 mm 42 mm 50 mm 52 mm 55 mm 60 mm 65 mm 70 mm 80 mm 90 mm 100 mm 110 mm 125 mm 0124296 0124297 0124298 0124299 0124300 0124...

Page 14: ...blade in direction of tool shank up to a cherry red colour 780o 810o C over the shortest distance possible approx 30 40 mm then quench in water with approx 20o C while constantly swinging tool around...

Page 15: ...ired minimum cross section ATTENTION The larger one of both cross sections has to be chosen Example Nominal voltage 3 400 V 50 Hz Rated current 15 A Line length 100 m 15 A x 100 m 1500 A x m Cross sec...

Page 16: ...SK00012GB 14 WIRING DIAGRAM Handle Plug Conducting Switch Screw union Capacitor Plug blue Plug red white yellow white yellow white red Engine white green white green white white red Electronic black...

Page 17: ...C and has been manufactured in accordance with the following directives 2000 14 EG 89 336 EG 98 37 EG 73 23 EG File certificate carefully EHB 10 230 EHB 10 240 0006943 0007081 0007082 0007083 0007087...

Page 18: ...16...

Page 19: ...DIN EN ISO 9001 CERTIFICATE...

Page 20: ...0 Fax 49 0 89 3 54 02 390 Wacker Corporation P O Box 9007 Menomonee Falls WI 53052 9007 Tel 1 1 262 255 0500 Fax 1 1 262 255 0550 Tel 800 770 0957 Wacker Asia Pacific Operations Skyline Tower Suite 23...

Page 21: ......

Page 22: ......

Reviews: