![Wacker Neuson 0008060 Operator'S Manual Download Page 31](http://html1.mh-extra.com/html/wacker-neuson/0008060/0008060_operators-manual_866546031.webp)
WP 1540A/AW
Maintenance
wpm_tx001130gb.fm
29
5.8
Air Cleaner
See Graphic: wc_gr000025
The engine is equipped with a dual element air cleaner. Service air
cleaner frequently to prevent carburetor malfunction.
NOTICE
: NEVER
run engine without air cleaner. Severe engine
damage will occur.
NEVER
use gasoline or other types of low flash point solvents for
cleaning the air cleaner. A fire or explosion could result.
To service:
5.8.1
Remove air cleaner cover
(a)
. Remove both elements and inspect
them for holes or tears. Replace damaged elements.
5.8.2
Wash foam element
(b)
in solution of mild detergent and warm water.
Rinse thoroughly in clean water. Allow element to dry thoroughly. Soak
element in clean engine oil and squeeze out excess oil.
5.8.3
Tap paper element
(c)
lightly to remove excess dirt. Replace paper
element if it appears heavily soiled.
WARNING
Summary of Contents for 0008060