background image

1A

OPERATION

STP

1A-8

1.16 Wiring Diagram

1

5

3

4

6

7

8

9

11

2

10

STP750

A

B

1

MOTOR WINDINGS

2

MOTOR PROTECTION SWITCH

3

CONNECTOR

4

CENTRIFUGAL SWITCH

5

START CAPACITOR

6

RESISTOR

7 RUN CAPACITOR
8 WIRE NUT
9 CONNECTOR

10 GROUND CONNECTION
11 POWER CABLE

A

B

STP 750 - 230V, 50 Hz

12.6 Ohm

3.9 Ohm

STP 750 - 115V, 60 Hz

3.5 Ohm

0.7 Ohm

1003SD15

3

2

4

5

6

7

8

9

STP400

1

MOTOR WINDINGS

2

MOTOR PROTECTION SWITCH

3

CONNECTOR

4

CENTRIFUGAL SWITCH

5

CAPACITOR

6 RESISTOR
7 CONNECTOR
8 GROUND CONNECTION
9 POWER CABLE

1010SD08

A

B

1

A

B

STP 400 - 115V, 50 Hz

3.2 Ohm

1.0 Ohm

STP 400 - 230V, 50 Hz

12.9 Ohm

3.9 Ohm

Summary of Contents for STP750

Page 1: ...www wackergroup com Pump STP400 STP750 OPERATOR S MANUAL 0154631en 001 0102 0 1 5 4 6 3 1 E N...

Page 2: ...68 IRELAND IRELAND IRELAND IRELAND IRELAND DUBLIN 13 127A BALDOYLE INDUSTRIAL ESTATE Tel 00353 01 8320218 Tel 00353 01 8320218 Tel 00353 01 8320218 Tel 00353 01 8320218 Tel 00353 01 8320218 ITALIA ITA...

Page 3: ...rating instructions carefully If you have questions about operating or servicing this equipment please contact Wacker Corporation The information contained in this manual was based on machines in prod...

Page 4: ...ummer Version und Maschinen Nummer ist an jedem Ger t angebracht Die Daten von diesem Schild bitte notieren damit sie auch bei Verlust oder Besch digung des Schildes noch vorhanden sind DerTyp dieArti...

Page 5: ...1 6 Application 1A 4 1 7 Installation 1A 5 1 8 Connection to Power Supply 1A 5 1 9 Operation 1A 5 1 10 Use of Extension Cords 1A 6 1 11 Motor Protection 1A 6 1 12 Periodic Maintenance 1A 6 1 13 Lubri...

Page 6: ...ity of improper service damage to the equipment or personal injury Notes Notes contain additional information important to a procedure CAUTION Cautions provide information important to prevent errors...

Page 7: ...areas exposed to flammable gases NEVER operate pump with covers loose or miss ing NEVER operate pump if power cord is damaged cut or worn Inspect power cable and extension cords often for damage NEVE...

Page 8: ...ive and pose severe health and envi ronmental hazards Contact local authorities for as sistance WARNING STP750 STP400 7650 7649 7648 7646 Index of Protection Rating 68 68 68 68 Voltage Volts 230 115 2...

Page 9: ...andle WARNING 1 8 Connection to Power Supply This pump is equipped with a 3 wire cord rated for outdoor use It is recommended that the pump be connected to a power source equipped with a ground fault...

Page 10: ...nnected WARNING 1 11 Motor Protection Thispumpisequippedwithbuilt inmotorprotection Ifthe pump overheats it will automatically turn itself off The pumpwillautomaticallyresetitselfandresumeoperation af...

Page 11: ...eller 1 15 Troubleshooting Problem Symptom Reason Remedy Pump does not start 1 Wrong voltage Check voltage requirements of pump 2 Blown fuse or open circuit breaker in power source 3 Damaged power cab...

Page 12: ...WIRE NUT 9 CONNECTOR 10 GROUND CONNECTION 11 POWER CABLE A B STP 750 230V 50 Hz 12 6 Ohm 3 9 Ohm STP 750 115V 60 Hz 3 5 Ohm 0 7 Ohm 1003SD15 3 2 4 5 6 7 8 9 STP400 1 MOTOR WINDINGS 2 MOTOR PROTECTION...

Page 13: ...dans la s rie du type de mat riel has been produced in accordance with the following standards in bereinstimmung mit folgenden Richtlinien hergestellt worden ist ha sido fabricado en conformidad con l...

Page 14: ...07563 82 76 85716 Unterschlei heim Fax 089 3 17 13 07 Tel 089 3 10 60 31 85077 Manching Fax 08459 76 02 Tel 08459 69 97 82538 Geretsried Fax 08171 3 14 09 Tel 08171 3 12 68 83064 Raubling Fax 08035 3...

Page 15: ...orreo 30 Tel 56 2 7400014 Antofagasta Orella 975 Tel 56 55 227250 Temuco Balmaceda 298 Tel 56 45 214425 AUSTRALIA CLAYTON VIC 3169 PO Box 1315 RMDC Tel 61 03 95474033 Norwood S A 5067 45 Beulah Road T...

Reviews: